background image

Calculite

®

HID Downlight  

C7E170VM

Page 2 of 2

7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Medium Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Job Information

Type:

2,250

4,500

3,000

1,500

4,500

6,000

2,250

4,500

6,750

9,000

30°

60°

30°

60°

30°

60°

70W ED17

- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM

ANGLE

MEAN CP

LUMENS

0

4470

5

4140

392

10

3669

15

3195

902

20

2664

25

2189

999

30

1590

35

1037

677

40

648

45

334

262

50

38

55

7

12

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

2292

40.22

70.66

0-40

2969

52.1

91.53

0-60

3243

56.91

99.99

0-90

3244

56.92

100

40-90

274

4.82

8.47

60-90

0

0.01

0.01

90-180

0

0

0

0-180

3244

56.92

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

16615

55

435

65

28

75

0

85

0

**  EFFICIENCY = 56.9%  **

CERTIFIED TEST REPORT NO. 2394FR, DATE: FEB 10, 2004

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.68

.68

.68

.68

.66

.66

.63

.63

.61

.61

.57

1

.65

.64

.63

.61

.63

.60

.60

.59

.58

.57

.54

2

.63

.60

.58

.57

.59

.56

.57

.55

.56

.54

.52

3

.60

.57

.55

.53

.56

.53

.55

.52

.54

.51

.49

4

.58

.54

.52

.50

.54

.49

.52

.49

.51

.48

.47

5

.55

.51

.49

.47

.51

.46

.50

.46

.49

.46

.44

6

.53

.49

.46

.44

.48

.44

.48

.44

.47

.43

.42

7

.51

.46

.43

.41

.46

.41

.45

.41

.45

.41

.40

8

.49

.44

.41

.39

.43

.39

.43

.39

.42

.39

.38

9

.46

.42

.39

.37

.41

.37

.41

.36

.40

.36

.35

10

.44

.39

.37

.34

.39

.34

.39

.34

.38

.34

.34

LUMINAIRE INPUT WATTS = 78

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

100W ED17

- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 8500 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM

ANGLE

MEAN CP

LUMENS

0

6144

5

5968

562

10

5465

15

4868

1372

20

4164

25

3520

1602

30

2639

35

1739

1130

40

1080

45

615

485

50

197

55

22

55

60

5

65

0

1

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3536

41.6

67.9

0-40

4666

54.9

89.6

0-60

5206

61.25

99.98

0-90

5207

61.27

100

40-90

541

6.37

10.4

60-90

1

0.01

0.02

90-180

0

0

0

0-180

5207

61.27

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

30624

55

1340

65

0

75

0

85

0

**  EFFICIENCY = 61.3%  ** 

CERTIFIED TEST REPORT NO. 2396FR, DATE: FEB 10, 2004

SC = .8

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.73

.73

.73

.73

.71

.71

.68

.68

.65

.65

.61

1

.70

.68

.67

.66

.67

.65

.65

.63

.62

.61

.58

2

.67

.65

.63

.61

.64

.60

.62

.59

.60

.58

.55

3

.64

.61

.58

.56

.60

.56

.59

.55

.57

.54

.53

4

.62

.58

.55

.53

.57

.52

.56

.52

.55

.51

.50

5

.59

.55

.51

.49

.54

.49

.53

.49

.52

.48

.47

6

.57

.52

.49

.46

.51

.46

.50

.46

.50

.46

.45

7

.54

.49

.46

.43

.49

.43

.48

.43

.47

.43

.42

8

.52

.46

.43

.41

.46

.41

.45

.40

.45

.40

.39

9

.49

.44

.40

.38

.43

.38

.43

.38

.42

.38

.37

10

.47

.41

.38

.36

.41

.36

.40

.36

.40

.35

.35

LUMINAIRE INPUT WATTS = 110

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

150W ED17

- PHILIPS CMH OPEN RATED LAMP-3K, LUMEN RATING = 11900 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR TRIM

ANGLE

MEAN CP

LUMENS

0

9142

5

8732

824

10

7907

15

6927

1952

20

5787

25

4726

2155

30

3385

35

2193

1440

40

1397

45

758

594

50

152

55

24

47

60

9

65

1

3

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

4930

41.44

70.3

0-40

6370

53.54

90.83

0-60

7011

58.92

99.96

0-90

7013

58.94

100

40-90

642

5.4

9.17

60-90

2

0.02

0.04

90-180

0

0

0

0-180

7013

58.94

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

37764

55

1454

65

66

75

0

85

0

**  EFFICIENCY = 58.9%  **

CERTIFIED TEST REPORT NO. 2395FR, DATE: FEB 10, 2004

SC = .8

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.70

.70

.70

.70

.69

.69

.65

.65

.63

.63

.59

1

.67

.66

.65

.64

.65

.63

.62

.61

.60

.59

.56

2

.65

.62

.60

.59

.61

.58

.59

.57

.58

.56

.54

3

.62

.59

.57

.55

.58

.54

.57

.53

.55

.53

.51

4

.60

.56

.53

.51

.55

.51

.54

.50

.53

.50

.48

5

.57

.53

.50

.48

.53

.48

.51

.47

.51

.47

.46

6

.55

.51

.47

.45

.50

.45

.49

.45

.48

.45

.44

7

.52

.48

.45

.43

.47

.42

.47

.42

.46

.42

.41

8

.50

.45

.42

.40

.45

.40

.44

.40

.44

.40

.39

9

.48

.43

.40

.38

.42

.38

.42

.37

.42

.37

.36

10

.46

.41

.38

.35

.40

.35

.40

.35

.39

.35

.34

LUMINAIRE INPUT WATTS = 167