background image

Job Information 

Type:

Lightolier 

a Genlyte company 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C0507

Calculite

®

 Evolution Incandescent Lensed Wall Washer 

C6P30L

Page 2 of 2 

6" Aperture PAR30 Reflector Trim

8

7

6

5

4

3

2

1

Perspec. Drawing Nos. 

Calculite Evolution

EXAMPLE: With multiple 75W PAR30 FL clear units
located 2’ from wall and 3’ on center, the illumination
on the wall 3’ down from the ceiling is 29 f.c. beneath 
and 18 f.c. between fixtures.

3'

2'

3'

29 f.c.

18 f.c.

 

 

2’ 

 

 

3’

1’ 

24 

13 

24 

13 

13

2’ 

52 

38 

52 

28 

15 

28

3’ 

39 

34 

39 

29 

18 

29

4’ 

25 

23 

25 

20 

16 

20

5’ 

16 

16 

16 

14 

12 

14

6’ 

11 

11 

11 

10 

10

7’ 

7

8’ 

5

9’ 

4

 

 

2’ 

 

 

3’

1’ 

4

2’ 

10 

10 

9

3’ 

15 

12 

15 

13 

13

4’ 

17 

14 

17 

14 

10 

15

5’ 

15 

14 

15 

13 

10 

13

6’ 

12 

12 

12 

10 

10

7’ 

10 

10 

10 

8

8’ 

6

9’ 

5

Units 3 Feet From Wall

Units 2 Feet From Wall

25˚

25˚

45˚

45˚

0929

Candlepower Curve

75W PAR30FL

Report 0927FR
Efficiency = 49.5%

Down 

Wall

Distance 

From 

Ceiling, 

Ft.

Distance 

From 

Ceiling, 

Ft.

For 50W Par30FL, Multiply f.c.’s by 0.55.

Footcandles values are averaged and rounded off and are based on a 
minimum of five units. For fixture-to-wall distances other than those 
shown.

Use maximum of 1 to 1 spacing (distance between fixtures not more than 
distance to wall) for best results

Lighting Data

Footcandles on Wall From Multiple Units - 75W PAR30 FL