6" Aperture PAR30 Reflector Trim
8
7
6
5
4
3
2
1
Perspec. Drawing Nos.
Calculite Evolution
EXAMPLE: With multiple 75W PAR30 FL clear units
located 2’ from wall and 3’ on center, the illumination
on the wall 3’ down from the ceiling is 29 f.c. beneath
and 18 f.c. between fixtures.
3'
2'
3'
29 f.c.
18 f.c.
2’
3’
1’
24
13
24
13
6
13
2’
52
38
52
28
15
28
3’
39
34
39
29
18
29
4’
25
23
25
20
16
20
5’
16
16
16
14
12
14
6’
11
11
11
10
9
10
7’
8
8
8
7
7
7
8’
6
6
6
5
5
5
9’
4
4
4
4
4
4
2’
3’
1’
4
3
4
4
2
4
2’
10
8
10
9
5
9
3’
15
12
15
13
8
13
4’
17
14
17
14
10
15
5’
15
14
15
13
10
13
6’
12
12
12
10
9
10
7’
10
10
10
8
7
8
8’
8
8
8
6
6
6
9’
6
6
6
5
5
5
Units 3 Feet From Wall
Units 2 Feet From Wall
5˚
5˚
25˚
25˚
45˚
45˚
0929
Candlepower Curve
75W PAR30FL
Report 0927FR
Efficiency = 49.5%
Down
Wall
Distance
From
Ceiling,
Ft.
Distance
From
Ceiling,
Ft.
For 50W Par30FL, Multiply f.c.’s by 0.55.
Footcandles values are averaged and rounded off and are based on a
minimum of five units. For fixture-to-wall distances other than those
shown.
Use maximum of 1 to 1 spacing (distance between fixtures not more than
distance to wall) for best results
Lighting Data
Footcandles on Wall From Multiple Units - 75W PAR30 FL