background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609

Job Information 

Type:

Calculite

®

 HID Downlight

  C4T4VM

Page 2 of 4 

4½" Aperture, 2pc Vertical, T4 Medium Beam

 ANGLE   MEAN CP   LUMENS

 

1595 

 

1524 

143

  10 

1345 

  15 

1109 

314

  20 

867 

  25 

649 

308

  30 

493 

  35 

396 

248

  40 

294 

  45 

125 

107

  50 

10 

  55 

2

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

764 

44.96 

68.13

  0-40 

1012 

59.56 

90.25

  0-60 

1121 

66 

100

  0-90 

1121 

66 

100

  40-90 

109 

6.43 

9.75

  60-90 

0

 90-180 

0

  0-180 

1121 

66 

100

20W T4 

GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat 20W Electronic Ballast CL Finish Trim

 750 

 1500 

1125 

375 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45 

17255 

 

55 

 39

 

65  

 0 

 

75 

 

85 

 0 

**EFFICIENCY = 66.0%** 

CERTIFIED TEST REPORT NO. 2322FR, DATE: OCT 04, 2003

SC = .7 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

 ANGLE   MEAN CP   LUMENS

 

2306 

 

2232 

211

  10 

2064 

  15 

1856 

523

  20 

1601 

  25 

1313 

616

  30 

1095 

  35 

902 

551

  40 

609 

  45 

243 

216

  50 

20 

  55 

6

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

39W T4 

Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat 39W Electronic Ballast, CL Finish Trim

 1250 

 2500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45 

33651

 

55 

466 

 

65  

0

 

75 

 

85 

**EFFICIENCY = 64.3%** 

CERTIFIED TEST REPORT NO. 2321FR, DATE: OCT 01, 2003 

SC = .8 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

  0-30 

1349 

40.9 

63.6

  0-40 

1900 

57.59 

89.56

  0-60 

2121 

64.3 

100

  0-90 

2121 

64.3 

100

  40-90 

221 

6.72 

10.44

  60-90 

0

 90-180 

0

  0-180 

2121 

64.3 

100

 ANGLE   MEAN CP   LUMENS

 

4707 

 

4560 

430

  10 

4188 

  15 

3667 

1032

  20 

3046 

  25 

2445 

1148

  30 

1987 

  35 

1587 

982

  40 

1090 

  45 

444 

390

  50 

38 

  55 

10

  60 

  65 

0

  70 

  75 

0

  80 

  85 

0

  90 

70W T4 

Philips CMH Lamp, Lumen Rating = 6400 LMS, Aromat 70W Electronic Ballast, CL Finish Trim

 2250 

 4500 

LUMINANCE SUMMARY CD. / SQ. M.

    ANGLE   MEAN CD/SQ M

 

45 

61418

 

55 

584

 

65  

 

75 

 

85 

**EFFICIENCY = 62.4%** 

CERTIFIED TEST REPORT NO. 2320FR, DATE: OCT 01, 2003

SC = .8 

COMPUTED BY LSI PROGRAM **TEST-LITE** 

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

  ZONE  LUMENS  % LAMP  %LUMINAIRE

   0-30 

2610 

40.79 

65.39

  0-40 

3592 

56.13 

89.97

  0-60 

3992 

62.38 

100

  0-90 

3992 

62.38 

100

  40-90 

400 

6.26 

10.03

  60-90 

0

 90-180 

0

  0-180 

3992 

62.38 

100

375

750

1125

1500

625

1250

1875

2500

1125

2250

3375

4500

30°

60°

30°

60°

30°

60°

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.79

.79

.79

.79

.77

.77

.74

.74

.71

.71 .66

1

.76

.74

.73

.72

.73

.71

.70 .68 .68 .66 .63

2

.73

.70 .68 .66 .69 .65

.67 .64 .65 .63 .60

3

.70 .66 .64

.61 .65

.61 .64 .60 .62 .59

.57

4

.67 .63 .60 .58 .62

.57

.61

.57 .60 .56 .54

5 .64 .60 .56 .54 .59 .54 .58 .53

.57 .53

.51

6 .62

.57 .53

.51 .56

.51 .55 .50 .54 .50

.49

7 .59 .53 .50

.48 .53

.47

.52

.47

.51

.47

.46

8 .56

.51

.47

.45 .50

.45

.49 .44

.49 .44 .43

9 .53

.48 .44

.42

.47

.42

.47

.42

.46

.42

.41

10

.51

.45

.42 .39

.45 .39 .44 .39 .44 .39 .38

LUMINAIRE INPUT WATTS = 23

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.77

.77

.77

.77

.75

.75

.72

.72 .69 .69 .65

1

.74

.72

.71

.70

.71 .68 .68 .66 .66 .64

.61

2

.71 .68 .66 .64

.67 .63 .65 .62 .63 .60 .58

3 .68 .64

.61 .59 .63

.59 .62 .58 .60

.57 .55

4 .65 .60

.57 .55 .60 .54 .58 .54

.57 .53

.52

5 .62

.57 .53

.51 .56

.51 .55 .50 .54 .50

.49

6 .59 .54 .50

.48 .53

.48

.52

.47

.51

.47

.46

7 .56

.51

.47

.45 .50 .44

.49 .44

.48 .44 .43

8 .53

.47 .44

.42

.47

.41

.46

.41

.46

.41

.40

9 .50

.45

.41 .39 .44 .39 .44 .38 .43 .38 .37

10

.48

.42 .38 .36

.42 .36

.41 .36

.41 .36 .35

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.74

.74

.74

.74

.73

.73

.70

.70

.67

.67 .63

1

.71

.70 .69

.67 .69 .66 .66 .64 .64 .62 .59

2 .68 .66 .64 .62 .65

.61 .63 .60

.61 .59 .56

3 .66 .62 .59

.57

.61

.57 .60 .56 .58 .55 .53

4 .63

.59 .56 .54 .58 .53

.57 .53 .56

.52

.51

5 .60 .56

.52 .50 .55 .50 .54

.49 .53

.49

.48

6

.57 .53

.49

.47

.52

.47

.51

.46 .50

.46

.45

7 .55

.49

.46 .44

.49 .44

.48

.43

.47 .43

.42

8

.52

.47 .43

.41

.46

.41

.46

.41

.45

.40 .39

9

.49 .44

.41 .38 .44 .38 .43 .38

.42 .38 .37

10

.47

.41 .38 .36

.41 .36

.41 .36

.40 .35 .34

LUMINAIRE INPUT WATTS = 78