4 1/2" Aperture (1) 20W CMH MR16
Job Information
Type:
500
1000
1500
2000
0°
30°
60°
90°
750
1500
2250
3000
0°
30°
60°
90°
C4MRDCCLW, 20W G.E. HID SPOT,
12° GX10 BASE
1750
3500
5250
7000
0°
30°
60°
90°
C4MRDCCLW, 20W G.E. HID FLOOD,
25° GX10 BASE
C4MRDCCLW, 20W G.E. HID FLOOD,
40° GX10 BASE
LUMEN RATING = 1000 LMS.
SC = .3
TEST REPORT NO. 3405FR
LUMEN RATING = 1000 LMS.
SC = .4
TEST REPORT NO. 3392FR
CANDLEPOWER SUMMARY
Angle
Mean CP Lumens
0
6795
5
5107
457
10 2136
15
803
293
20
386
25
207
108
30
134
35
52
42
40
30
45
16
12
50
0
55
0
0
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
LUMINANCE SUMMARY
ANGLE
MEAN CD/SQ M
45
2475
55
0
65
0
75
0
85
0
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC
80
70
50
30
10
CU VALUE GREATER THAN 1.00
determined in accordance with current IES published procedures
LUMINAIRE INPUT WATTS = 26.0
WALL 70 50 30 10
70 50 30 10
50 30 10 50 30 10 50 30 10 0
RCR
0 1.09 1.09 1.09 1.09 1.06 1.06 1.06 1.06 1.01 1.01 1.01 .97 .97 .97 .93 .93 .93 .91
1 1.06 1.04 1.03 1.02 1.04 1.03 1.01 1.00 .99 .98 .97 .95 .95 .94 .92 .92 .91 .90
2 1.03 1.01 .98 .96 1.01 .99 .97 .95 .96 .95 .93 .94 .93 .92 .91 .91 .90 .88
3 1.01 .97 .95 .93 .99 .96 .94 .92 .94 .92 .91 .92 .91 .90 .91 .89 .88 .87
4 .99 .95 .92 .90 .98 .94 .92 .90 .92 .90 .89 .91 .89 .88 .89 .88 .87 .86
5 .97 .93 .90 .88 .95 .92 .89 .87 .90 .88 .87 .89 .87 .86 .88 .87 .85 .84
6 .95 .91 .88 .86 .94 .90 .87 .85 .89 .87 .85 .88 .86 .84 .87 .85 .84 .83
7 .93 .89 .86 .84 .92 .88 .86 .83 .87 .85 .83 .86 .84 .83 .86 .84 .82 .82
8 .92 .87 .84 .82 .91 .86 .84 .82 .86 .83 .82 .85 .83 .81 .84 .83 .81 .80
9 .90 .85 .83 .81 .89 .85 .83 .81 .84 .82 .80 .84 .82 .80 .83 .81 .80 .79
10 .88 .84 .81 .79 .88 .84 .81 .79 .83 .81 .79 .82 .80 .79 .82 .80 .79 .78
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS %LAMP %LUMINAIRE
** EFFICIENCY = 91.2% **
0-30
857
85.75
94.06
0-40
899
89.97
98.69
0-60
911
91.16
100.00
0-90
911
91.16
100.00
40-90
11
1.19
1.31
60-90
0
.00
.00
90-180
0
.00
.00
0-180
911
91.16
100.00
CANDLEPOWER SUMMARY
Angle
Mean CP Lumens
0
3280
5
2896
267
10
2105
15
1316
386
20
715
25
342
184
30
187
35
92
67
40
53
45
30
22
50
0
55
0
0
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
LUMINANCE SUMMARY
ANGLE
MEAN CD/SQ M
45
4709
55
0
65
0
75
0
85
0
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC
80
70
50
30
10
CU VALUE GREATER THAN 1.00
determined in accordance with current IES published procedures
LUMINAIRE INPUT WATTS = 26.0
WALL 70 50 30 10
70 50 30 10
50 30 10 50 30 10 50 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08 1.08 1.03 1.03 1.03 .98 .98 .98 .94 .94 .94 .93
1 1.07 1.05 1.04 1.02 1.05 1.04 1.02 1.01 1.00 .99 .98 .96 .95 .95 .93 .93 .92 .91
2 1.04 1.01 .99 .96 1.02 .99 .97 .95 .96 .95 .93 .94 .93 .91 .92 .91 .90 .88
3 1.01 .97 .94 .92 1.00 .96 .94 .92 .94 .92 .90 .92 .90 .89 .90 .89 .87 .86
4 .98 .94 .91 .89 .97 .93 .91 .88 .92 .89 .87 .90 .88 .86 .88 .87 .85 .84
5 .96 .91 .88 .85 .95 .90 .87 .85 .89 .86 .84 .87 .85 .83 .86 .85 .83 .82
6 .94 .89 .85 .83 .93 .88 .85 .83 .87 .84 .82 .86 .83 .82 .85 .83 .81 .80
7 .91 .86 .83 .80 .90 .85 .82 .80 .84 .82 .80 .83 .81 .79 .83 .80 .79 .78
8 .89 .83 .80 .78 .88 .83 .80 .77 .82 .79 .77 .81 .79 .77 .81 .78 .77 .76
9 .87 .81 .78 .76 .86 .81 .78 .76 .80 .77 .75 .80 .77 .75 .79 .76 .75 .74
10 .85 .79 .76 .73 .84 .79 .76 .73 .78 .75 .73 .78 .75 .73 .77 .75 .73 .72
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS %LAMP %LUMINAIRE
** EFFICIENCY = 92.5% **
0-30
836
83.67
90.41
0-40
903
90.33
97.61
0-60
925
92.54
100.00
0-90
925
92.54
100.00
40-90
22
2.21
2.39
60-90
0
.00
.00
90-180
0
.00
.00
0-180
925
92.54
100.00
LUMEN RATING = 1000 LMS.
SC = .6
TEST REPORT NO. 3391FR
CANDLEPOWER SUMMARY
Angle
Mean CP Lumens
0
2247
5
1983
187
10
1629
15
1300
366
20
934
25
504
255
30 261
35
120
88
40
62
45
37
27
50
5
55
1
2
60
1
65
1
1
70
0
75
0
0
80
0
85
0
0
90
0
LUMINANCE SUMMARY
ANGLE
MEAN CD/SQ M
45
5737
55
260
65
211
75
157
85
200
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC
80
70
50
30
10
CU VALUE GREATER THAN 1.00
determined in accordance with current IES published procedures
LUMINAIRE INPUT WATTS = 26.0
WALL 70 50 30 10
70 50 30 10
50 30 10 50 30 10 50 30 10 0
RCR
0 1.10 1.10 1.10 1.10 1.08 1.08 1.08 1.08 1.03 1.03 1.03 .99 .99 .99 .95 .95 .95 .93
1 1.07 1.05 1.03 1.02 1.05 1.03 1.02 1.00 .99 .98 .97 .96 .95 .94 .93 .92 .92 .90
2 1.03 1.00 .98 .95 1.02 .99 .96 .94 .96 .94 .92 .93 .92 .91 .91 .90 .89 .87
3 1.00 .96 .93 .91 .99 .95 .92 .90 .93 .91 .89 .91 .89 .87 .89 .88 .86 .85
4 .97 .93 .89 .87 .96 .92 .89 .86 .90 .87 .85 .88 .86 .84 .87 .85 .83 .82
5 .94 .89 .85 .83 .93 .88 .85 .82 .87 .84 .82 .86 .83 .81 .84 .82 .80 .79
6 .92 .86 .83 .80 .91 .86 .82 .80 .85 .82 .79 .83 .81 .79 .82 .80 .78 .77
7 .89 .83 .79 .77 .88 .83 .79 .76 .82 .78 .76 .81 .78 .76 .80 .77 .75 .75
8 .87 .80 .77 .74 .86 .80 .76 .74 .79 .76 .74 .78 .75 .73 .77 .75 .73 .72
9 .84 .78 .74 .71 .83 .77 .74 .71 .76 .73 .71 .76 .73 .71 .75 .72 .70 .70
10 .81 .75 .72 .69 .81 .75 .72 .69 .74 .71 .69 .74 .71 .68 .73 .70 .68 .67
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS %LAMP %LUMINAIRE
** EFFICIENCY = 92.7% **
0-30
807
80.79
87.15
0-40
896
89.63
96.69
0-60
925
92.56
99.85
0-90
926
92.70
100.00
40-90
30
3.07
3.31
60-90
1
.14
.15
90-180
0
.00
.00
0-180
926
92.70
100.00
Tested according to IES procedures.
Test distance exceeds five times the greatest luminous opening of luminaire.
Tested according to IES procedures.
Test distance exceeds five times the greatest luminous opening of luminaire.
Tested according to IES procedures.
Test distance exceeds five times the greatest luminous opening of luminaire.