background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2012 Philips Group • B0312

Calculite

®

 HID Downlight

 C4MRD

Page 2 of 2 

4 1/2" Aperture (1) 20W CMH MR16 

Job Information 

Type:

 500 

 1000 

 1500 

 2000 

30°

60°

90°

 750 

 1500 

 2250 

 3000 

0° 

30°

60°

90°

C4MRDCCLW, 20W G.E. HID SPOT,

 12° GX10 BASE

 1750 

 3500 

 5250 

 7000 

30°

60°

90°

C4MRDCCLW, 20W G.E. HID FLOOD,

 25° GX10 BASE

C4MRDCCLW, 20W G.E. HID FLOOD,

 40° GX10 BASE

LUMEN RATING = 1000 LMS.

SC =  .3

TEST REPORT NO. 3405FR

LUMEN RATING = 1000 LMS.

SC =  .4

TEST REPORT NO. 3392FR

CANDLEPOWER SUMMARY

Angle

Mean CP Lumens

 

6795

 

5107 

457

 10  2136

 

15 

803 

293

 

20 

386

 

25 

207 

108

 

30 

134

 

35 

52 

42

 

40 

30

 

45 

16 

12

 

50 

0

 

55 

0

 60 

0

 

65 

0

 70 

0

 

75 

0

 

80 

0

 

85 

0

 

90 

0

LUMINANCE SUMMARY

ANGLE

MEAN CD/SQ M 

 

45 

2475

 

55 

0

 

65 

0

 

75 

0

 

85 

0

COEFFICIENTS OF UTILIZATION 

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC

80

70

50

30

10

CU VALUE GREATER THAN 1.00

determined in accordance with current IES published procedures

LUMINAIRE INPUT WATTS =  26.0

  WALL  70  50  30  10 

70  50  30  10 

50  30  10  50  30  10  50  30  10  0

 RCR

 

0  1.09  1.09  1.09  1.09  1.06  1.06  1.06  1.06  1.01  1.01  1.01  .97  .97  .97  .93 .93 .93  .91

 

1  1.06  1.04  1.03  1.02  1.04  1.03  1.01  1.00  .99  .98  .97  .95 .95 .94  .92 .92  .91  .90

 

2  1.03  1.01  .98  .96  1.01  .99  .97  .95  .96  .95  .93  .94 .93 .92  .91  .91 .90  .88

 

3  1.01  .97  .95  .93  .99  .96  .94  .92  .94  .92  .91  .92  .91 .90  .91 .89 .88  .87

 

4  .99  .95  .92  .90  .98  .94  .92  .90  .92  .90  .89  .91 .89 .88  .89 .88 .87  .86

 

5  .97  .93  .90  .88  .95  .92  .89  .87  .90  .88  .87  .89 .87 .86  .88 .87 .85  .84

 

6  .95  .91  .88  .86  .94  .90  .87  .85  .89  .87  .85  .88 .86 .84  .87 .85 .84  .83

 

7  .93  .89  .86  .84  .92  .88  .86  .83  .87  .85  .83  .86 .84 .83  .86 .84 .82  .82

 

8  .92  .87  .84  .82  .91  .86  .84  .82  .86  .83  .82  .85 .83  .81  .84 .83  .81  .80

 

9  .90  .85  .83  .81  .89  .85  .83  .81  .84  .82  .80  .84 .82 .80  .83  .81 .80  .79

 

10  .88  .84  .81  .79  .88  .84  .81  .79  .83  .81  .79  .82 .80  .79  .82 .80  .79  .78

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS %LAMP %LUMINAIRE

**  EFFICIENCY = 91.2%  **

  0-30 

857 

85.75 

94.06

  0-40 

899 

89.97 

98.69

  0-60 

911 

91.16 

100.00

  0-90 

911 

91.16 

100.00

  40-90 

11 

1.19 

1.31

  60-90 

.00 

.00

  90-180 

.00 

.00

  0-180 

911 

91.16 

100.00

CANDLEPOWER SUMMARY

Angle

Mean CP Lumens

 

3280

 

2896 

267

 

10 

2105

 

15 

1316 

386

 

20 

715

 

25 

342 

184

 

30 

187

 

35 

92 

67

 

40 

53

 

45 

30 

22

 

50 

0

 

55 

0

 60 

0

 

65 

0

 70 

0

 

75 

0

 

80 

0

 

85 

0

 

90 

0

LUMINANCE SUMMARY

ANGLE

MEAN CD/SQ M 

 

45 

4709

 

55 

0

 

65 

0

 

75 

0

 

85 

0

COEFFICIENTS OF UTILIZATION 

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC

80

70

50

30

10

CU VALUE GREATER THAN 1.00

determined in accordance with current IES published procedures

LUMINAIRE INPUT WATTS =  26.0

  WALL  70  50  30  10 

70  50  30  10 

50  30  10  50  30  10  50  30  10  0

 RCR

 

0  1.10  1.10  1.10  1.10  1.08  1.08  1.08  1.08  1.03  1.03  1.03  .98 .98 .98  .94 .94 .94  .93

 

1  1.07  1.05  1.04  1.02  1.05  1.04  1.02  1.01  1.00  .99  .98  .96 .95 .95  .93 .93 .92  .91

 

2  1.04  1.01  .99  .96  1.02  .99  .97  .95  .96  .95  .93  .94 .93  .91  .92  .91 .90  .88

 

3  1.01  .97  .94  .92  1.00  .96  .94  .92  .94  .92  .90  .92 .90 .89  .90 .89 .87  .86

 

4  .98  .94  .91  .89  .97  .93  .91  .88  .92  .89  .87  .90 .88 .86  .88 .87 .85  .84

 

5  .96  .91  .88  .85  .95  .90  .87  .85  .89  .86  .84  .87 .85 .83  .86 .85 .83  .82

 

6  .94  .89  .85  .83  .93  .88  .85  .83  .87  .84  .82  .86 .83 .82  .85 .83  .81  .80

 

7  .91  .86  .83  .80  .90  .85  .82  .80  .84  .82  .80  .83  .81  .79  .83 .80  .79  .78

 

8  .89  .83  .80  .78  .88  .83  .80  .77  .82  .79  .77  .81  .79  .77  .81  .78  .77  .76

 

9  .87  .81  .78  .76  .86  .81  .78  .76  .80  .77  .75  .80  .77  .75  .79  .76  .75  .74

 

10  .85  .79  .76  .73  .84  .79  .76  .73  .78  .75  .73  .78  .75  .73  .77  .75  .73  .72

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS %LAMP %LUMINAIRE

**  EFFICIENCY = 92.5%  **

  0-30 

836 

83.67 

90.41

  0-40 

903 

90.33 

97.61

  0-60 

925 

92.54 

100.00

  0-90 

925 

92.54 

100.00

  40-90 

22 

2.21 

2.39

  60-90 

.00 

.00

  90-180 

.00 

.00

  0-180 

925 

92.54 

100.00

LUMEN RATING = 1000 LMS.

SC =  .6

TEST REPORT NO. 3391FR

CANDLEPOWER SUMMARY

Angle

Mean CP Lumens

 

2247

 

1983 

187

 

10 

1629

 

15 

1300 

366

 

20 

934

 

25 

504 

255

 30  261

 

35 

120 

88

 

40 

62

 

45 

37 

27

 

50 

5

 

55 

2

 60 

1

 

65 

1

 70 

0

 

75 

0

 

80 

0

 

85 

0

 

90 

0

LUMINANCE SUMMARY

ANGLE

MEAN CD/SQ M 

 

45 

5737

 

55 

260

 

65 

211

 

75 

157

 

85 

200

COEFFICIENTS OF UTILIZATION 

ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

CC

80

70

50

30

10

CU VALUE GREATER THAN 1.00

determined in accordance with current IES published procedures

LUMINAIRE INPUT WATTS =  26.0

  WALL  70  50  30  10 

70  50  30  10 

50  30  10  50  30  10  50  30  10  0

 RCR

 

0  1.10  1.10  1.10  1.10  1.08  1.08  1.08  1.08  1.03  1.03  1.03  .99 .99 .99  .95 .95 .95  .93

 

1  1.07  1.05  1.03  1.02  1.05  1.03  1.02  1.00  .99  .98  .97  .96 .95 .94  .93 .92 .92  .90

 

2  1.03  1.00  .98  .95  1.02  .99  .96  .94  .96  .94  .92  .93 .92  .91  .91 .90 .89  .87

 

3  1.00  .96  .93  .91  .99  .95  .92  .90  .93  .91  .89  .91 .89 .87  .89 .88 .86  .85

 

4  .97  .93  .89  .87  .96  .92  .89  .86  .90  .87  .85  .88 .86 .84  .87 .85 .83  .82

 

5  .94  .89  .85  .83  .93  .88  .85  .82  .87  .84  .82  .86 .83  .81  .84 .82 .80  .79

 

6  .92  .86  .83  .80  .91  .86  .82  .80  .85  .82  .79  .83  .81  .79  .82 .80  .78  .77

 

7  .89  .83  .79  .77  .88  .83  .79  .76  .82  .78  .76  .81  .78  .76  .80  .77  .75  .75

 

8  .87  .80  .77  .74  .86  .80  .76  .74  .79  .76  .74  .78  .75  .73  .77  .75  .73  .72

 

9  .84  .78  .74  .71  .83  .77  .74  .71  .76  .73  .71  .76  .73  .71  .75  .72  .70  .70

 

10  .81  .75  .72  .69  .81  .75  .72  .69  .74  .71  .69  .74  .71 .68  .73  .70 .68  .67

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS %LAMP %LUMINAIRE

**  EFFICIENCY = 92.7%  **

  0-30 

807 

80.79 

87.15

  0-40 

896 

89.63 

96.69

  0-60 

925 

92.56 

99.85

  0-90 

926 

92.70 

100.00

  40-90 

30 

3.07 

3.31

  60-90 

.14 

.15

  90-180 

.00 

.00

  0-180 

926 

92.70 

100.00

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

Tested according to IES procedures.

Test distance exceeds five times the greatest luminous opening of luminaire.

Отзывы: