background image

SPACING RATIO = 0.9

DATE: July 20, 1999
PREPARED FOR
LIGHTOLIER, FALL RIVER, MA

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES  

THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

DATE: AUG. 23, 1999
PREPARED FOR
LIGHTOLIER, FALL RIVER, MA

ROOM CA

VITY RA

TIO

 

                     

 COEFFICIENTS OF UTILIZATION

  

            

                             % EFFECTIVE FLOOR CAVITY REFLECTANCE 

          

          8 0                           7 0                           5 0                           3 0                           1 0

                                 

 % WALL REFLECTANCE

            5 0     3 0     1 0      5 0     3 0    1 0      5 0     3 0     1 0       5 0     3 0     1 0       5 0     3 0     1 0       

0
1       . 4 7  . 4 6   . 4 5   . 4 6   . 4 5   . 4 5  . 4 4   . 4 4  . 4 1   . 4 1   . 4 2   . 4 2  . 4 1   . 4 1  . 4 1   . 4 0
 2 .       4 5  . 4 3   . 4 2   . 4 4   . 4 3   . 4 2  . 4 2   . 4 2  . 4 1   . 4 1   . 4 1   . 4 0  . 4 0   . 4 0  . 3 9   . 3 9
 3 .       4 2  . 4 1   . 3 9   . 4 2   . 4 0   . 3 9  . 4 1   . 4 0   . 3 9   . 4 0   . 3 9   . 3 8  . 3 9   . 3 8  . 3 7   . 3 7
 4       . 4 0  . 3 9   . 3 7   . 4 0   . 3 8   . 3 7  . 3 9   . 3 8   . 3 7   . 3 8   . 3 7   . 3 6  . 3 8   . 3 7  . 3 6   . 3 5
 5       . 3 9  . 3 7   . 3 5   . 3 8   . 3 6   . 3 5  . 3 7   . 3 6   . 3 5   . 3 7   . 3 5   . 3 4  . 3 6   . 3 5  . 3 4   . 3 4
 6       . 3 7 . 3 5   . 3 4   . 3 7   . 3 6   . 3 3  . 3 6   . 3 4  . 3 3   . 3 5   . 3 4   . 3 3  . 3 5   . 3 4  . 3 3   . 3 2
 7       . 3 5 . 3 3   3 2   . 3 5   . 3 3   . 3 2  . 3 4   . 3 3  . 3 2   . 3 4   . 3 2   . 3 1  . 3 4   . 3 2  . 3 1   . 3 1
8       . 3 4 . 3 2   . 3 0   . 3 3   . 3 1   . 3 0  . 3 3   . 3 1   . 3 0   . 3 3   . 3 1   . 3 0  . 3 2   . 3 1  . 3 0   . 2 9
9         3 2 . 3 0   . 2 9   . 3 2   . 3 0   . 2 9  . 3 1   . 3 0   . 2 9   . 3 1   . 3 0   . 2 8  . 3 1   . 2 9  . 2 8   . 2 8
1 0     . 3 1 . 2 9   . 2 7   . 3 0   . 2 9   . 2 7  . 3 0   . 2 8   . 2 7   . 3 0   . 2 8   . 2 7  . 3 0   . 2 8  . 2 7   . 2 7
                   20% FLOOR CAVITY REFLECTANCE
Conversion Factors:
60W to 100W MB19: Clear, C.U.x 1.00: Diffuse, C.U.x 0.85;  Gold C.U.x0.9

TESTED ACCORDING TO IES PROCEDURES. TESTED DISTANCE EXCEEDS FIVE TIMES THE 

GREATEST LUMINOUS OPENING OF LUMINAIRE.

COEFFICIENTS OF UTILIZATION

 % EFFECTIVE CEILING CAVITY REFLECTANCE

        

 80 

70  

50 

30 

10 

0

 % WALL REFLECTANCE

  

 50   30   10   50   30   10   50   30   10   50   30   10   50   30   10   0

 

1   . 5 7   . 5 6   . 5 5   . 5 6   . 5 5   . 5 4   . 5 4   . 5 3   . 5 3   . 5 2   . 5 2   . 5 1   . 5 1   . 5 0   . 5 0  . 4 9

 

2   . 5 4   . 5 3   . 5 1   . 5 3   . 5 2   . 5 1   . 5 2   . 5 1   . 5 0   . 5 0   . 4 9   . 4 9   . 4 9   . 4 8   . 4 8  . 4 7

 

3   . 5 1   . 4 9   . 4 8   . 5 1   . 4 9   . 4 8   . 5 0   . 4 8   . 4 7   . 4 8   . 4 7   . 4 6   . 4 7   . 4 6   . 4 5  . 4 5

 

4   . 4 9   . 4 7   . 4 5   . 4 9   . 4 7   . 4 5   . 4 8   . 4 6   . 4 4   . 4 7   . 4 5   . 4 4   . 4 6   . 4 4   . 4 3  . 4 3

 

5   . 4 7   . 4 4   . 4 2   . 4 6   . 4 4   . 4 2   . 4 5   . 4 3   . 4 2   . 4 4   . 4 3   . 4 2   . 4 4   . 4 2   . 4 1  . 4 1

 

6   . 4 5   . 4 2   . 4 0   . 4 4   . 4 2   . 4 0   . 4 3   4 1   . 4 0   . 4 3   . 4 1   . 4 0   . 4 2   . 4 1   . 3 9  . 3 9

 

7   . 4 2   . 4 0   . 3 8   . 4 2   . 4 0   . 3 8   . 4 1   . 3 9   . 3 8   . 4 1   . 3 9   . 3 8   . 4 0   . 3 9   . 3 7  . 3 7

 

8   . 4 0   . 3 8   . 3 6   . 4 0   . 3 8   . 3 6   . 3 9   . 3 7   . 3 6   . 3 9   . 3 7   . 3 6   . 3 9   . 3 7   . 3 5  . 3 5

 

9   . 3 8   . 3 6   . 3 4   . 3 8   . 3 6   . 3 4   . 3 8   . 3 5   . 3 4   . 3 7   . 3 5   . 3 4   . 3 7   . 3 5   . 3 4  . 3 3

  10  .36 .34 .32 .36 .34 .32 .36 .34 .32 .35 .33 .32 .35 .33 .32 .31

20% FLOOR CAVITY REFLECTANCE

ROOM CA

VITY RA

TIO

Conversion Factors

40W to 100W A19: Clear, C.U. x 1.00: Diffuse, C.U. x 0.85; Gold C.U. 0.90

60W to 100W BT15: Clear, C.U. x 0.85: Diffuse, C.U. x 0.70; Gold C.U. x 0.75

 CERTIFIED TEST REPORT NO. 0836FR

COMPUTED BY LSI PROGRAM **TEST-LITE**

RECESSED OPEN REFLECTOR DOWNLIGHT

4 1/2" DIA. APERTURE, SPECULAR CLEAR FINISH REFLECTOR 

100W A-19 PHILIPS LAMP. LUMEN RATING = 1600 LMS.

SPACING RATIO = 0.6

8

7

6

5

4

3

2

1

Perspec. Drawing Nos. 

Calculite Evolution

Calculite® Evolution Incandescent Open Downlight 

C4AD

Page 2 of 2 

4 1/2” Aperture A19 / MB19 / BT15 Reflector Trim

Lightolier 

a Genlyte Thomas Company 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Thomas Group LLC (Lightolier Division) • C0711