background image

Lighting Systems

 

Baselyte-BSL4

Page  of 7   

 Light T5 HO Direct/Indirect

Job Information 

Type:

 
Job Name: 
Cat. No.: 

 

Lamp(s): 
Notes: 

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Ordering Information

Family

H

 = T5 HO

6

 = Direct/

Indirect

01

CN           

H

6

BSL

CN

 = Cutout  

  w/baffles

04

 = 4’

08

 = 8’

12

 = 2’

1

 = cct.

= cct.  

w/EC/NL

5

 = cct.  

w/EM Battery

7

 = cct.  

w/Dimming

= cct. w/cct.  

Thru wire

= Standard  

<0% THD

= Standard  

<0% THD  
w/fusing  

C

 = Custom Color

W

 = Standard

 

  White

Distribution

Lamp Type

No. of Lamps

Housing

Module Length

Wiring 

Voltage

Ballast

Finish

Weight = 3.0 lb./ft

01 

=  Light

Note:

 Please

consult wiring
section of spec
sheets for more 
wiring options.

Specifications

Features

.  Housing: die-formed 20ga. cold rolled steel
2.  End Set: die-cast metal with baked powder coat finish
3.  Lamping: one T5 HO lamp
4.  Configuration: 4’, 8’ and 2’ module lengths or continuous rows
5.  Ballasts: electronic 20V or 277V

Finish

High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.

Mounting

Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements. 

Electrical

All luminaires are factory pre-wired to module ends with quick-wire 
connectors.

Joints & Intersections

Self-aligning joining system with hands-free pre-joining wire access.

Labels

UL, CSA standards.

Individual Fixtures

.  Determine the number of individual modules required
2.  Order one end set per module
3.  Order one non-power mount per module
4.  Order one power mount per module

Continuous Rows*

.  Determine run length
2.  Order the appropriate number and length of modules for complete run 
3.  Order one end set for each run
4.  Order one non-power mount for each module
5.  Order one power mount per run
6.  Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)

*Note

: Some runs may require additional power mounts. Please see the  

‘Run Configuration’ table on the next page for more details.

Ordering Instructions

D

 = Dual 20V   

& 277V 

1

 = 20V

2

 = 277V 

Note:

 Option‘D’ is

standard. Voltage
options  and 2 are
only available with
EM Battery and 
Dimming wiring
options.

Содержание Baselyte-BSL4

Страница 1: ...ty white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjustment capability Aircraf...

Страница 2: ...5 90 180 1047 1047 1047 1047 1047 175 1042 1042 1047 1049 1050 165 1002 1011 1034 1051 1058 155 930 951 1007 1051 1067 0 145 826 867 965 1043 1070 1 135 694 766 912 1025 1062 2 125 541 651 850 993 10...

Страница 3: ...anded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7...

Страница 4: ...ength 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSL...

Страница 5: ...uctor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x...

Страница 6: ...erformance CTP1300 Type P Bodine high performance LP600 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trig...

Страница 7: ...ions with Emergency Battery Pack EM Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru...

Отзывы: