Job Information 

Type:

Performance

Candlepower Curve

Candlepower Summary

Coefficients of Utilization

Report No:

 990057

Lamps: 

F54T5

Lumens per Lamp: 

4650

Efficiency: 

7.5%

Up:

 93.3%  

Down:

 6.7%

Zonal Lumen Summary

ZONE        LUMENS        %BARE LAMP       %LUMINAIRE

CANDLEPOWER SUMMARY

ZONE

CANDLEPOWER

DEG.

0

45

90

135

180

180

633

633

633

633

633

175

685

673

631

599

581

165

742

678

612

478

414

155

912

740

575

338

367

145

1100

846

527

337

352

135

1303

946

469

309

321

125

1516

1040

401

266

264

115

1589

1113

305

199

200

105

864

921

171

129

136

95

168

195

31

60

71

90

48

23

1

9

15

85

60

31

3

3

3

75

79

46

7

3

3

65

93

61

12

4

4

55

102

72

22

7

5

45

105

79

34

10

7

35

102

82

45

19

13

25

94

80

53

32

24

15

83

75

59

45

40

5

70

68

62

57

55

0

63

63

63

63

63

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

69

69

69

60

60

60

42

42

42

1

60

57

54

51

49

47

36

35

34

2

52

48

44

45

41

39

32

29

28

3

45

40

36

39

35

32

28

25

23

4

40

35

31

34

30

27

24

22

19

5

35

30

26

30

26

23

22

19

16

6

31

26

22

27

23

19

19

16

14

7

28

23

19

24

20

17

17

14

12

8

25

20

16

22

17

14

15

13

10

9

23

18

14

20

15

13

14

11

9

10 21

16

13

18

14

11

13

10

8

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

3324

3102

222

6.7
93.3
100.0

4.8
66.7
71.5

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

69

69

69

60

60

60

42

42

42

1

60

57

54

51

49

47

36

35

34

2

52

48

44

45

41

39

32

29

28

3

45

40

36

39

35

32

28

25

23

4

40

35

31

34

30

27

24

22

19

5

35

30

26

30

26

23

22

19

16

6

31

26

22

27

23

19

19

16

14

7

28

23

19

24

20

17

17

14

12

8

25

20

16

22

17

14

15

13

10

9

23

18

14

20

15

13

14

11

9

10 21

16

13

18

14

11

13

10

8

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

3324

3102

222

6.7
93.3
100.0

4.8
66.7
71.5

Module Lengths & Mounting Distances

Run Configuration 

Run

Length

 

4’ 

Module

8’

Module

2’ 

Module

Joiner

End Set

Mount

Power 

Mount*

4’ run

8’ run

2’ run

6’ run

2

2

20’ run

2

24’ run

2

2

28’ run

2

2

3

32’ run

2

3

-ODULE,ENGTH

-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

@

@

@

Joiner

BSLEWW

 = wall mount standard white

End Set

BSLJW

 = wall mount joiner 

System Components & Accessories

Non-Power Wall Mount

Power Wall Mount

BSLWP1 

= -power mount

BSLWP2 

= 2-power mount

BSLWN

 = non-power wall mount

Note

: Shaded area indicates locations of emergency sections (emergency wiring  

controls all lamps or optional battery pack controls one or two lamps).

*Note

: Additional power mounts may be required for some runs with T5 HO 

lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.

Отзывы: