background image

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • C0609

Architectural Decorative

  4A28

Page 2 of 2 

Pendalux Cirrus 28” Diameter Body 4-26/32/42 Triple Tube

Features

1.  Diffusing Reflector:

 White translucent acrylic, 3/16” thick.

2.  Inner Dirt Shield:

 White translucent acrylic, 1/8” thick.

3.  Chassis:

 Steel, 20 gauge, semi-gloss white powder-coat finish.

4.  Suspension:

 Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia., 

fastened internally, no exposed hardware. Permits installation on ceilings 
with slope of up to 45°. Complies with California Code.

5.  Lampholder:

 Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 

lamp base.

Lamping (by others)

Compact Fluorescent:

 Triple Tube, 26, 32, or 42 Watts.

   

General Electric 

Osram/Sylvania 

Philips

26W Triple Tube 4-Pin     (Amalgam) Compact      Fluorescent Lamp
 

F26TBX/*/A/4P 

CF26DT/E/IN/* 

PL-T26W/*/4P

32W Triple Tube 4-Pin     (Amalgam) Compact      Fluorescent Lamp
 

F32TBX/*/A/4P 

CF32DT/E/IN/* 

PL-T32W/*/4P

42W Triple Tube 4-Pin     (Amalgam) Compact      Fluorescent Lamp
 

F42QBK/*/A/4P 

CF42DT/E/IN/* 

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast:

 Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage 

120/277V, Multi-Wattage 26/32/42W.

4 Lamps

 

26 Watt 

32Watt  

42Watt

Voltage

 

120V   277V  120V   277V  120V   277V

Total Input Watts

 

110 

110 

140 

140  186 

186

Max. Line Current (amps)

 1.11 

0.48  1.40 

0.60  0.60 

0.80

Power Factor

 

>0.98  >0.98  >0.98  >0.98  >0.99  >0.99

Ballast Factor

 

1.02  1.02  0.96  0.96  0.95 

0.95

THD<10%

 Minimum Starting Temperature: -5°F/-20°C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

28 Inch Diameter
30’ x 30’ x 10’ Space
Luminaire 

Spacing: 10’ x 10’

 

Susp. Dist. 28”

4 Lamps

26W
TTT

32W
TTT

42W
TTT

Illum. (FC)
Maint.

30

41

54

Lum.
Ratio

8/1

8/1

9/1

Watts/
Sq. Ft.

1.10

1.36

1.86

Reflectances: 80% Ceiling, 50% Walls, 20% Floor. 
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

ROOM

 CA

VITY

 RA

TIO

            COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

                   %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

80 

70 

50 

30 

10

 

50  30  10     50  30  10   50  30  10   50  30  10   50  30  10    0 

  1 

.68 .65 .63  .60 .57 .54  .44 .42 .41  .29 .28 .27  .15 .15 .14  .08

 

  2 

.59 .55 .51  .52 .48 .45  .38 .35 .33  .25 .24 .22  .13 .13 .12  .07

 

  3 

.52 .47 .42  .46 .41 .37  .33 .30 .28  .22 .21 .19  .12 .11 .10  .06

 

  4 

.46 .40 .36  .40 .35 .32  .30 .26 .24  .20 .18 .16  .10 .10 .09  .05

 

  5 

.40 .35 .30  .36 .31 .27  .26 .23 .20  .18 .15 .14  .09 .08 .08  .04

 

  6 

.36 .30 .26  .32 .27 .23  .24 .20 .17  .16 .14 .12  .08 .07 .07  .04

 

  7 

.32 .26 .22  .28 .23 .20  .21 .18 .15  .14 .12 .10  .08 .06 .06  .03

 

  8 

.38 .29 .19  .26 .21 .17  .19 .16 .13  .13 .11 .09  .07 .06 .05  .03

 

  9 

.36 .26 .17  .23 .18 .15  .17 .14 .11  .12 .09 .08  .06 .05 .04  .02

 

 10 

.33 .24 .15  .21 .16 .13  .16 .12 .10  .11 .08 .07  .06 .05 .04  .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ANGLE  MEAN CP  LUMENS

  0 

  395

  5 

394  

38

10 

389

15 

382  

108

20 

372

25 

360  

166

30 

342

35 

321  

201

40 

297

45 

272  

211

50 

247

55 

221  

198

60 

193

65 

165  

165

70 

141

75 

116  

123

80 

  92

85 

  71  

    78

90 

  53  

 

ANGLE  MEAN CP  LUMENS

  90 

53

  95 

121  

199

100 

433

105 

834  

871

110 

1193

115 

1470  

1453

120 

1722

125 

1912  

1704

130 

2053

135 

2149  

1656

140 

2203

145 

2215  

1386

150 

2192

155 

2178  

1005

160 

2136

165 

1949  

546

170 

1666

175 

1624  

159

180 

1756

CERTIFIED TEST REPORT NO. 4A28442    

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE                 

CAT. #4A28442APBU, HOUSING COVER WITHOUT FLANGE, 28” DIFFUSER              

4-42W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 3200 LMS.                

2-ADVANCE BALLAST, #ICF-2S42-M2-LD, 120 VAC

TESTED ACCORDING TO IES PROCEDURES.  TEST DISTANCE EXCEEDS FIVE 

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ZONE 

LUMENS 

% LAMP 

%LUMINAIRE

0-30 

311   

2.43 

3.03

0-40 

512   

4.01 

 

5.00

0-60 

920   

7.20 

 

8.97

0-90 

1287   

10.06 

 

12.54

40-90 

774   

6.05 

 

7.55

60-90 

366   

2.86 

 

3.57

90-180 

8978 

70.15 

 

87.46

0-180 

10266   

80.21 

 

100.00

**  EFFICIENCY = 80.2%  **

C

ANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

DATE: OCT. 4, 2000

PREPARED FOR:

LIGHTOLIER, FALL RIVER, MA

Отзывы: