background image

Alter 

Tilelyte 

QVD

 

2 x 2

Page 2 of 2 

2’ x 2’ Recessed  Direct/Indirect Fluorescent

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

  0 

1856 

1856 

1856 

1856 

1856

  5 

1846 

1845 

1842 

1847 

1854

10 

1814 

1812 

1818 

1816 

1820

15 

1762 

1760 

1759 

1773 

1767

20 

1685 

1684 

1695 

1694 

1694

25 

1598 

1598 

1591 

1596 

1599

30 

1481 

1484 

1484 

1484 

1489

35 

1363 

1361 

1364 

1369 

1369

40 

1234 

1239 

1234 

1236 

1236

45 

1090 

1099 

1091 

1091 

1103

50 

 941 

948 

941 

941 

949

55 

 798 

795 

799 

807 

806

60 

 654 

651 

652 

659 

655

65 

 514 

507 

513 

505 

509

70 

 376 

371 

369 

372 

382

75 

 242 

240 

241 

240 

244

80 

 125 

121 

126 

126 

123

85 

35 

 34 

 25 

 31 

 26

90 

0

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

  

 

 

 

  

 

 

  

 

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

  0  .58  .58  .58  .58  .57  .57  .57  .57  .54  .54  .54

  1  .54  .52  .50  .48  .53  .51  .49  .48  .49  .47  .46

  2  .50  .46  .43  .41  .49  .45  .43  .40  .44  .41  .39

  3  .46  .41  .38  .35  .45  .40  .37  .35  .39  .36  .34

  4  .42  .37  .33  .30  .41  .36  .33  .30  .35  .32  .30

  5  .39  .33  .29  .26  .38  .33  .29  .26  .32  .28  .26

  6  .36  .30  .26  .23  .35  .30  .26  .23  .29  .25  .23

  7  .33  .27  .23  .20  .32  .27  .23  .20  .26  .22  .20

  8  .31  .25  .21  .18  .30  .24  .20  .18  .24  .20  .18

  9  .29  .22  .18  .16  .28  .22  .18  .16  .21  .18  .16

 10  .27  .20  .17  .14  .26  .20  .17  .14  .20  .16  .14

        

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 99.8

Room Cavity Ratio

ZONE 

LUMENS 

% LAMP 

%LUMINAIRE

0-30 

1406 

14.89 

30.45

0-40 

2258 

23.90 

48.88

0-60 

3812 

40.35 

82.51

0-90 

4620 

48.90 

100.00

40-90 

2362 

25.00 

51.12

60-90 

808 

8.55 

17.49

90-180 

 0 

 .00 

 .00

0-180 

4620 

48.90 

100.00

DISTRIBUTION

CANDLEPOWER CURVE 3FT

Performance

CANDLEPOWER

REPORT NO: LSCA677
CAT. NO: QVD2GGLOP3FT120X3

3 40W TT5 Compact Fluorescent Lamps at 3150 lumens. 

Efficiency: 48.9% 

Candela at Nadir: 1856cd

90°

90°

180°

800

1600

2400       

 

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

  0 

1315 

1315 

1315 

1315 

1315

  5 

1305 

1303 

1316 

1316 

1317

10 

1287 

1284 

1286 

1291 

1291

15 

1249 

1248 

1249 

1251 

1252

20 

1200 

1202 

1201 

1200 

1206

25 

1135 

1132 

1137 

1135 

1148

30 

1053 

1065 

1060 

1061 

1064

35 

 970 

975 

971 

980 

979

40 

 878 

882 

881 

891 

890

45 

 785 

779 

784 

783 

786

50 

 677 

680 

674 

683 

681

55 

 576 

572 

571 

578 

580

60 

 469 

477 

474 

477 

478

65 

 375 

372 

371 

370 

373

70 

 277 

276 

270 

273 

280

75 

 184 

182 

178 

181 

183

80 

96 

 92 

 91 

 96 

 93

85 

31 

 20 

 20 

 20 

 21

90 

0

COEFFICIENTS OF UTILIZATION

ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

  

 

 

 

  

 

 

  

 

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

  0  .56   .56  .56  .56  .55  .55  .55  .55  .52  .52  .52

  1  .52  .50  .48  .47  .51  .49  .47  .46  .47  .46  .44

  2  .48  .44  .41  .39  .47  .43  .41  .38  .42  .40  .38

  3  .44  .39  .36  .33  .43  .39  .35  .33  .37  .35  .32

  4  .40  .35  .31  .28  .39  .35  .31  .28  .33  .30  .28

  5  .37  .31  .27  .24  .36  .31  .27  .24  .30  .26  .24

  6  .34  .28  .24  .21  .33  .28  .24  .21  .27  .23  .21

  7  .31  .25  .21  .19  .31  .25  .21  .18  .24  .21  .18

  8  .29  .23  .19  .16  .28  .22  .19  .16  .22  .18  .16

  9  .27  .21  .17  .14  .26  .20  .17  .14  .20  .16  .14

 10  .25  .19  .15  .12  .24  .18  .15  .12  .18  .15  .12

        

 

 

 

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE INPUT WATTS = 95.7

Room Cavity Ratio

ZONE 

LUMENS 

% LAMP 

%LUMINAIRE

0-30 

1000 

14.21 

30.14

0-40 

 1608 

22.84 

48.46

0-60 

 2725 

38.72 

82.14

0-90 

 3318 

47.14 

100.00

40-90 

1710 

24.30 

51.54

60-90 

 592 

 8.42 

17.86

90-180 

  0 

  .00 

  .00

0-180 

3318 

47.14 

100.00

DISTRIBUTION

CANDLEPOWER CURVE 424

Performance

CANDLEPOWER

REPORT NO: LSCA934
CAT. NO: QVD2GGLOP424120PG

4 24W T5HO Fluorescent Lamps at 1760 lumens.  

Efficiency: 47.1% 

Candela at Nadir: 1315cd

90°

90°

180°

400

800

1200       

 

Job Information

Type:

For Factory Technical Information: (978) 657-7600

Fax (978) 658-0595

11/10

631 Airport Road, Fall River, MA 02720

(508) 679-8131

Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.