"MFSPOÜ4FSJFT-JHIU51FSh DN4FDUJPO

$

Fixture Lengths and Mounting Locations

A1TES24ALD

= Alu

m

inu

m

A1TES24WHD

= White

Dual Power Feed End Set
5 Wires (2-12 ga., 3-18ga.) on One End

A1TES24ALS

= Alu

m

inu

m

A1TES24WHS

= White

Single Power Feed End Set 
5 Wires (2-12 ga., 3-18ga.) on One End

AC36

Inter

m

ediate

36" (91.44c

m

) Cable Set

ALS24

Inter

m

ediate 

24" (60.96c

m

) White Ste

m

 Set

ACC36X4

Inter

m

ediate 36" (91.44c

m

)

Cable & 4 Wire 18 ga.
Cord Set for Fluorescent Only

A1LAL

= Alu

m

inu

m

A1LWH

= White

"L" Joiner Block 

A1TAL

= Alu

m

inu

m

A1TWH

= White

"T" Joiner Block

A1XAL

= Alu

m

inu

m

A1XWH

= White

"X" Joiner Block

A1ILAL

= Alu

m

inu

m

A1ILWH

= White

Inline Joiner Block

ATCAL

= Alu

m

inu

m

ATCWH

= White

Track Adapter

7"

(17.78c

m

)

7" (17.78c

m

)

6"

(15.24c

m

)

12" (30.48c

m

)

7"

(17.78c

m

)

12"

(30.48c

m

)

12" (30.48c

m

)

12" (30.48c

m

)

4-7/16"

(11.27c

m

)

Mounting Accessories

3 Wires (2-12 ga. 1-18ga.) on One End
24" (60.96c

m

)  Ste

m

s for Track

24" (60.96c

m

) Ste

m

s for Track     

6"
(15.24c

m

)

6"
(15.24c

m

)

96” (243.84c

m

)

144” (365.76c

m

)

20’ 7” (627.38c

m

)

20-Foot

12’ 7” (383.54c

m

)

144” (365.76c

m

)

12-Foot

48” (121.92c

m

)

4-Foot

4’ 7” (139.87c

m

)

8-Foot

8’ 7” (261.62c

m

)

96” (243.84c

m

)

CANDLEPOWER CURVE

CANDLEPOWER

ZONE        0

22

45           67           90

DEG.

CANDELAS

Performance

REPORT NO: ITL50917
CAT NO: AIX4C54 
LAMPS: 1-F54T5
LUMENS: 5000
EFFICIENCY: 58.7%

DISTRIBUTION
Zone

Lumens

% Lamp

% Luminaire

0-90

1198

24.0

41 .0

90-180

1736

34.7

59.0

0-180

2934

58.7

100.0

600

450

300

150

0

10

20

30

40

50

60

70

80

9090

100

110

120

130

140

150

160

170

180

ROOM CA

VITY RA

TIO

70

50

30

70

50

30

50

30

10

0

62

62

62

56

56

56

46

46

46

1

55

52

49

50

47

44

38

36

35

2

49

44

40

45

40

37

33

30

28

3

45

38

34

40

35

31

28

25

23

4

41

34

29

37

31

26

25

21

19

5

37

30

25

33

27

23

22

19

16

6

34

27

22

31

24

20

20

16

14

7

31

24

19

28

22

17

18

14

12

8

29

22

17

26

20

15

16

13

10

9

27

20

15

24

18

14

15

11

9

10 26

18

14

23

17

12

13

10

8

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

WALL REFLECTANCE

20% FLOOR CAVITY REFLECTANCE

180
175
165
155
145
135
125
115
105

95
90
85
75
65
55
45
35
25
15

5
0

601
592
521
431
345
261
183
144

78
19

7

58

107
144
181
208
230
244
253
257
256

601
594
513
414
321
237
159

94

105
115

98

104
132
158
182
208
231
246
254
257
256

601
582
480
393
337
264
153
283
280
207
174
155
151
187
206
210
224
241
253
256
256

601
582
486
444
417
298
271
401
344
256
201
175
175
215
228
227
225
239
252
256
256

601
570
485
486
434
316
414
424
352
262
222
195
186
216
230
230
225
236
250
255
256

4' (121.92c

m

)

Module

8' (243.84c

m

Module

12' (365.76c

m

Module

End Set Suspension

4' (121.92c

m

) Run

1

1

8' (243.84c

m

) Run

1

1

12' (365.76c

m

) Run

1

1

16' (487.68c

m

) Run

2

1

1

20' (609.60c

m

) Run

1

1

1

1

24' (731.52c

m

) Run

2

1

1

Отзывы: