background image

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2009 Philips Group • C0609

Architectural Decorative

  4A23

Page 2 of 2 

Pendalux Cirrus 23” Diameter Body 2-26/32/42 Triple Tube

Features

1.  Diffusing Reflector:

 White translucent acrylic, 3/16” thick.

2.  Inner Dirt Shield:

 White translucent acrylic, 1/8” thick.

3.  Chassis:

 Steel, 20 gauge, semi-gloss white powder-coat finish.

4.  Suspension:

 Swivel (central) stem, 5/8” steel tube. Canopy, 7” Dia., 

fastened internally, no exposed hardware. Permits installation on ceilings 
with slope of up to 45°. Complies with California Code.

5.  Lampholder:

 Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4 

lamp base.

Lamping (by others)

Compact Fluorescent:

 Triple Tube, 26, 32, or 42 Watts.

   

General Electric 

Osram/Sylvania 

Philips

26W Triple Tube 4-Pin    (Amalgam) Compact      Fluorescent Lamp
 

F26TBX/*/A/4P 

CF26DT/E/IN/* 

PL-T26W/*/4P

32W Triple Tube 4-Pin     (Amalgam) Compact      Fluorescent Lamp
 

F32TBX/*/A/4P 

CF32DT/E/IN/* 

PL-T32W/*/4P

42W Triple Tube 4-Pin     (Amalgam) Compact      Fluorescent Lamp
 

F42QBK/*/A/4P 

CF42DT/E/IN/* 

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast:

 Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage

120/277V, Multi-Wattage 26/32/42W.

2 Lamp

 

26 Watt 

32Watt  

42Watt

Voltage

 

120V   277V  120V   277V  120V   277V

Total Input Watts

 

55 

55 

70 

70 

93 

93

Max. Line Current (amps)

  0.55  0.24  0.70  0.30  0.30  0.40

Power Factor

 

>0.98  >0.98  >0.98  >0.98  >0.99  >0.99

Ballast Factor

 

1.02  1.02  0.96  0.96  0.95  0.95

THD<10%

 Minimum Starting Temperature: -5°F/-20°C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus Suitable for Damp Locations.

Application Data

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor. 
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

ANGLE  MEAN CP  LUMENS

  195

193  

18

10 

191

15 

189  

 53

20 

184

25 

177  

 82

30 

169

35 

158  

 99

40 

148

45 

137  

106

50 

126

55 

113  

101

60 

100

65 

  88  

 87

70 

  76

75 

  64  

 68

80 

  53

85 

  42  

 47

90 

  38

CERTIFIED TEST REPORT NO. 4A23242A    

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE                 

CAT. #4A23242, 23” DIFFUSER              

2-42W T/E SYLVANIA  LAMPS. LUMEN RATING = 3200 LMS.                

ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC

TESTED ACCORDING TO IES PROCEDURES.  TEST DISTANCE EXCEEDS FIVE 

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ANGLE  MEAN CP  LUMENS

  90 

38

  95 

80  

121

100 

245

105 

437  

456

110 

604

115 

735  

725

120 

848

125 

949  

848

130 

1035

135 

1091  

842

140 

1133

145 

1140  

713

150 

1125

155 

1103  

507

160 

1051

165 

  956  

267

170 

  812

175 

  647  

65

180 

  598

C

ANDLEPOWER SUMMARY

DATE: DEC. 11, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

ROOM

 CA

VITY

 RA

TIO

            COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

                   %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

80 

70 

50 

30 

10

 

50  30  10     50  30  10   50  30  10   50  30  10   50  30  10    0

 

  1 

.69 .66 .63  .60 .58 .55  .44 .43 .41  .29 .28 .27  .15 .15 .15  .08

 

  2 

.60 .55 .51  .53 .49 .45  .38 .36 .34  .25 .24 .23  .13 .13 .12  .07

 

  3 

.53 .47 .43  .46 .42 .38  .34 .31 .28  .22 .21 .19  .12 .11 .10  .06

 

  4 

.47 .41 .36  .41 .36 .32  .30 .27 .24  .20 .18 .16  .11 .10 .09  .05

 

  5 

.41 .35 .30  .36 .31 .27  .27 .23 .20  .18 .16 .14  .09 .08 .08  .04

 

  6 

.37 .31 .26  .32 .27 .23  .24 .20 .18  .16 .14 .12  .08 .07 .07  .04

 

  7 

.33 .27 .22  .29 .24 .20  .21 .18 .15  .14 .12 .10  .08 .06 .06  .03

 

  8 

.30 .24 .20  .26 .21 .17  .19 .16 .13  .13 .11 .09  .07 .06 .05  .03

 

  9 

.27 .21 .17  .23 .19 .15  .17 .14 .12  .12 .10 .08  .06 .05 .04  .02

 

 10 

.24 .19 .15  .21 .17 .13  .16 .13 .10  .11 .08 .07  .06 .05 .04  .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ZONAL LUMENS AND PERCENTAGES

ZONE 

LUMENS % LAMP %LUMINAIRE

0-30 

153   

2.40 

2.95

0-40 

252   

3.95 

 

4.86

0-60 

459   

7.18 

 

8.83

0-90 

661   

10.34 

 

12.72

40-90 

409   

6.39 

 

7.86

60-90 

202   

3.16 

 

3.88

90-180 

4543 

70.98 

 

87.28

0-180 

5204   

81.33 

 

100.00

**  EFFICIENCY = 81.3%  **

23 Inch Diameter
24’ x 24’ x 9.5’ Space
Luminaire   

Spacing: 8’ x 8’

 

 

Susp. Dist. 24”

2 Lamps   

26W 

32W 

42W

 

 

TTT 

TTT 

TTT

Illum. (FC)   

22 

29 

40

Maint.

Lum. 

 

7/1 

7/1 

8/1

Ratio

Watts/ 

 

0.85 

1.06 

1.45

Sq. Ft.

Отзывы: