background image

ENGLISH 

Specifications: 

Troubleshooting: 

The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the 
manufacturer, the dealer or the corresponding specialist personnel. Never open the device on 

your own! 

If the specified corrections have not led to success, please contact our service staff. The contact 
details can be found at www.musicstore.de 

Model 

lightmaXX Vector Haze 1.7 

Power supply 

AC220-240V 50/60Hz 

Power consumption 

1650 Watt 

Fog fluid tank capacity 

5 Liter 

Fog fluid consumption 

1-42ml/min

DMX connection 

3-pol

DMX channels 

Power connection 

Power

 Twist

 

Fuse 

250/10A 

Dimensions (L x W x H) 

660 x 300 x 610 mm 

Weight 

34 Kg 

Symptom 

Troubleshooting 

No function 

Check the mains connection and the fuse 

No fog output 

Check the fill level of the fluid container 

No reaction in DMX mode 

Check the cable connections 
Check your DMX address setting 

If available, try an alternative DMX controller 

No reaction in remote mode 

Change the battery in your remote control 
Ensure that the IR transmitter and receiver are at 

close and clear distances from each other 

Содержание Vector Haze 1.7

Страница 1: ... DANGER For babies and children Dispose of or store any packaging material properly Packaging material must be kept out of the reach of babies and children due to the risk of suffocation Ensure that children never use the appliance unattended In addition make sure that children do not remove small parts from the device as they could suffocate by swallowing parts Hint Fire and injure hazard due to ...

Страница 2: ...s such as power amplifiers or mixing consoles DMX cables enable trouble free operation and the highest possible transmission reliability of signal data Do not use microphone cables Hint Condensation To avoid condensation in the unit the unit should adapt to the ambient temperature before commissioning Hint Unwanted odours A new product can sometimes lead to unwanted odours This reaction is normal ...

Страница 3: ...e The installation of the device should always be carried out by experienced personnel and must be carried out in compliance with the mechanical and electrical safety regulations in your country Hint Fog fluid Disconnect the device from the mains before filling Do not fill with hot liquids Only use high quality water based fog fluids recommended by your dealer Other fog fluids can lead to clogging...

Страница 4: ...7453 Tel 49 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product LightmaXX Vector Haze 1 7 is used exclusively for the generation of artificial fog by vaporizing the filled fog fluid The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and...

Страница 5: ...n on the device itself Display and menu buttons The device has 4 operating keys and an LCD display on which all settings can be addressed and read Button Function Description Interval Set 5 200sec Duration Set 5 200sec Timer mode setting Timer Out 1 100 Menu Volume Out 1 100 Fan Speed 1 100 DMX Add 001 512 Fluid sensor on off Timer Up Up Activate Timer function Volume Down Down Activate Volume fun...

Страница 6: ...the timer mode Setting the Fog Level for Volume Mode To adjust the fog quantity press Menu until the display shows Volume out Use the Up Down buttons to adjust the fog volume from 1 to 100 This setting is required if you want to use the option Volume Continuous Mode Setting the fan speed To set the fan speed press Menu until the display shows Fan Speed Use the Up Down buttons to set the fan speed ...

Страница 7: ... the timer mode The display indicates the set time interval Interval xxx s The unit counts down to 0 seconds and emits fog To deactivate the timer mode press the Stop button Volume Continuous Mode Press the VOLUME button to activate continuous fog output The display indicates Volume followed by the value that was set in menu item Volume Out Duration xxx s To stop the fog output press the Stop butt...

Страница 8: ...MX software or the DMX output of a device already in your DMX chain Always use a DMX cable with a 110 Ohm resistor for this connection Address the device according to your DMX configuration The following table shows the respective DMX modes of the individual devices with the corresponding values and functions Channel Value Function 1 000 005 Off 006 255 1 100 Fan Speed 2 000 005 Off 006 255 1 100 ...

Страница 9: ...ENGLISH Connections and controls ...

Страница 10: ...ation 1 Output nozzle 8 Fuse 2 Fan 9 Power input Power Twist 3 Air baffle adjustable 10 DMX Out 3 pol 4 Castors 11 DMX In 3 pol 5 Butterfly lock for removable cover 12 Display 6 Carrying handle 13 Menu buttons 7 Fluid tank compartment ...

Страница 11: ...r consumption 1650 Watt Fog fluid tank capacity 5 Liter Fog fluid consumption 1 42ml min DMX connection 3 pol DMX channels 2 Power connection Power Twist Fuse 250 10A Dimensions L x W x H 660 x 300 x 610 mm Weight 34 Kg Symptom Troubleshooting No function Check the mains connection and the fuse No fog output Check the fill level of the fluid container No reaction in DMX mode Check the cable connec...

Страница 12: ...set the output to Zero and wait for minimum 30 seconds before to switch off the unit This allows the unit to execute its cleaning process so all the remaining fluid is removed from the internal circuits Switch off the unit unplug the mains cable and wait 10 minutes until the unit has been cooled down During inspection the following points should be checked All screws used for installing the device...

Страница 13: ... on the packaging Disposal of batteries Batteries do not belong in the garbage Please keep batteries in accordance with the official collection points or disposal stations in accordance with the specifications Disposal of your old device Do not dispose of the device with household waste This device is subject to the WEEE Directive Waste Electrical and Electronic Equipment in its currently valid ve...

Страница 14: ...ENGLISH MS ID LIG0016334 000 09 2019 Notes ...

Отзывы: