Preliminary Manual
35
RDM operation
The Laserlink supports RDM operation. RDM is Remote Device Management.
While DMX-512 is unidirectional protocol RDM can communicate with the device via the standard
DMX cable.
When RDM is enabled the protocol inserts data packets into the DMX-512 stream.
For this the RDM controller can send and receive commands/messages from the Laserlink.
Software like
Super Nova
from
Lumenradio
can be used for configuration.
GrandMA2 Software is faulty. There are no negative values possible.
Here is an overview of the RDM commands:
General RDM Commands:
Parameter ID
Set Command
Get Command
PRODUCT_DETAILED_ID
x
DEVICE_MODEL_DESCRIPTION
x
MANUFACTURER_LABEL
x
LANGUAGE_CAPABILITIES
x
DMX_PERSONALITY_DESCRIPTION
x
DEVICE_LABEL
x
x
LANGUAGE
x
x
DMX_PERSONALITY
x
x
DMX_START_ADDRESS
x
x
IDENTIFY_DEVICE
x
x
MS Artnet Net
x
x
MS Artnet Subnet
x
x
MS Artnet DMX universe
x
x
Содержание Laserlink