3
3
For MIDI Channel, select an unused channel or channels. Up to four cards can be set to a single channel with a different
MIDI NOTE Range for each card. Refer to the MIDI NOTE RANGE and MIDI CHANNEL charts for switch selection.
The X indicates the switch is set to the ON position.
Switch in the ON position.
Detecting Pistons.
There is a minor difference in the procedure for detecting Division Pistons and General Pistons.
DIVISION PISTONS. Select a Division piston, for example GREAT #1 piston on the screen and with the mouse, Right
Click and select Auto Detect. On the organ console, push the Great #1 piston and DONE should light on the screen, click on
DONE. Repeat the procedure for each Division piston on each manual.
GENERAL PISTONS. This is a two step process, first right click on a screen General piston, select Auto Detect and push
the corresponding console General Piston. Done should light, click on Done.
Step 2, right click on the same screen General Piston and select “Adjust MIDI Trigger Setting”. The following screen will
open. Select the Primary output tab and change the following.
1. Output: to MIDI note on/off
2. MIDI OUT All enabled ports
3. MIDI Channel, and be any channel
4. Note: change to 127.
5. Click the OK button.
What this does is when a General piston is pushed, it will cancel all the Division pistons that were set before a General piston
was pushed.
CANCEL PISTON
. For the Cancel Piston, follow steps
1 and 2, the same sequence as with the General pistons.
Set the OUTPUT to MIDI NOTE 127.
Содержание LPC-1