The products referred to in this manual conform to the European Community Directives to which
they are subject:
Low Voltage 2014/35/EU
Electromagnetic Compatibility 2014/30/EU

Never look directly into the light source. You risk injury to your retina, which may induce blindness.

Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may 

concentrate the light output.

Protection optical radiation

Protection against explosion

The protection screen, lens or ultraviolet screen on the lamp can be damaged to the degree 

of failure if visible damage, such as a crack or deep mark, should be replaced

The light source in this xture shall be replaced by the manufacturer or its service agent or 

similar qualication.

Always disconnect from mains before replacing the light.

3

t

c

 

60℃

The maximun temperature that can be reached on the external surface of the fitting,

in a thermally steady state,is 60

℃。

Avoid contact bypersons and materials. 

Allow the fixture to cool for at least 5 minutes before handling. 

光源

The light source

The product implementation standard.

GB

 

7000

.

1

-

2015

   

GB7000

.

217

-

2008

Содержание TX0760

Страница 1: ...E mail n Add No 51 Yunfeng Rd Xinhua Industrial Zone Xinhua Street Huadu District Guangzhou China TX0760ZOOM Please read these user manual carefully before use...

Страница 2: ...viced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Страница 3: ...ng a potential fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture This lighting fixture is for professional use only it is not for hou...

Страница 4: ...osion The protection screen lens or ultraviolet screen on the lamp can be damaged to the degree of failure if visible damage such as a crack or deep mark should be replaced The light source in this xt...

Страница 5: ...set Automatic chang battery IP could be set without electricity Software upgrade Insert USB upgrade software IP20 protection IP20 Protected against the entry of solid bodies larger than 12mm No protec...

Страница 6: ...ft in 6 5 Diameter m ft in 50 Diameter m ft in 3 9 10 0 6 3 7 4 23 3 7 23 1 4 4 7 9 1 29 10 5012 466 10120 941 12376 221 28535 2652 221 21 398 37 102 9 1205 112 1065 99 2235 208 538 50 6558 609 49 5 9...

Страница 7: ...power cord 6 425 188 506 300 436 ATTACHMENT AND BODY SIZE...

Страница 8: ...support structure of the projector and then connected to the fixing point at the centre of the base 7 Make sure all parts for fixing the projector are in a good state of repair Make sure the point of...

Страница 9: ...sure all the devices had been installed with natural operate press the power switch to check whether every thing is working normally L N Ground connection to the eiectricty mains must be carried out...

Страница 10: ...put 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 The projector all the projectors are together dn t touch each other...

Страница 11: ...se LED chip s brightness and wave length can not be produced exactly same by LED factory which would cause the color difference in the LED color fixture To solve the issue LIGHT SKY adopts a calibrati...

Страница 12: ...0 RDM UID Undistributed Fan speed Voltag Fan1 1 0000 RPM Fan2 2 0000 RPM DMX live 1 Pan 2 Pan 3 TILT 4 TILT Fine 5 Fuction 6 Dimmer 7 Shutter 8 Red 9 Green 10 Blue 11 White 12 Macro 13 ZOOM System ver...

Страница 13: ...FF ON Tilt invert OFF ON Return ESC Language English Chinese Display Back Light Open Auto close 15s Reversal Normal Rota 180 Backlight blink ON OFF Return ESC Main menu menu menu menu Return ESC Dimme...

Страница 14: ...an Developer Firmware update Return ESC return ESC DMX ARTNET First DMX ARTNET First ARTNET IP Address Service ARTNET Channel control 5 Fuction 6 Dimmer 7 Shutter 8 Red 9 Green 10 Blue 11 White 12 Mac...

Страница 15: ...ARTNET Mask Address Net Address Sub Net Address Net Universe Address return ESC Language English Chinese Reversal Normal Rota 180 Main menu menu menu menu 14...

Страница 16: ...mmerSpeed4 96 255 37 6 100 No Fuction 6 0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119...

Страница 17: ...0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119 35 3 46 7 Slow closing Slow open Slow F...

Страница 18: ...Speed3 86 95 33 7 37 3 DimmerSpeed4 96 255 37 6 100 No Fuction 6 0 255 0 100 Dimmer 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow...

Страница 19: ...00 No Fuction 6 0 255 0 100 7 Shutter 0 9 0 3 5 NO Function 10 49 3 9 19 2 Slow closing Fast opening slow fast 50 89 19 6 34 9 Fast closing Slow opening Slow Fast 90 119 35 3 46 7 Slow closing Slow op...

Страница 20: ...TEM 20170831 B W R P1 P4 P8 P5 U U U U D1 7A 250V 1 J1 7A 250V 1 J2 1 J3 0160 FG2 V1 0 TEM 20170831 B W R P1 P4 P8 P5 U U U U D1 7A 250V 1 J1 7A 250V 1 J2 1 J3 0160 FG2 V1 0 TEM 20170831 B W R P1 P4...

Страница 21: ...e down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged...

Страница 22: ...o long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipmen...

Страница 23: ...above step by step Please check the belt of the X Y is broken Please check the X Y direction data to the receiver is damage Re projector reset On working the pan tilt couldn t work normally the data w...

Страница 24: ...E mail n Add No 51 Yunfeng Rd Xinhua Industrial Zone Xinhua Street Huadu District Guangzhou China...

Отзывы: