TROUBLE DISPOSE
It is recommended some solution for some normal trouble shooting. Any inextricability
problems should always be handling by the professional person. Disconnect the power
supply before maintenance the light.
●
LED off:
1.
Please check if install the suitable voltage
2.
Please check whether the led will reach the end of their life can explode; please
replace a same description led.
3.
Please check if the power supply is enough.
4.
Please check whether the DMX 512 controller pass the "turn on" order.
●
Though the light is lighting, but it couldn't accept the control order:
1.
Please check the start code address and the function option are correct.
2.
Please check whether the communicate control cable is on good connection or the
cable is too long or interrupt.
3.
Please check the control system is not valid, check the signal amplifier of chain
connected is valid.
4.
Please check whether the communicate cable is too long or the other equipment is
mutually conjugate.
5.
Please arrange the wire well, shorter the signal cable, put the high voltage cable
and low voltage cable separately.
6.
Add the signal amplify isolator.
7.
Signal cable is used the excellent screening doublet (Resistance 75 OHM)
8.
The end of the light end and the end resistance.
●
The light can't move:
1.
Please check if the power supply is suitable for the light voltage data.
2.
Please check the light if they are deformation, inside parts is broken, become wet
etc will lead the loose contact.