background image

15

CHANNEL

 

table

 

(

steamline

  

14CH

)

Channe

DMX

Percentage

Function

Colour

0-4
5-8

9-12

13-17

18-21

22-25
26-29
30-34
35-38
39-42
43-46
47-51
52-55
56-59
60-63
64-68
69-72

77-81
82-85

86-89
90-93
94-98

99-102

103-106

73-76

107-110
111-115
116-119
120-123
124-127
128-191
192-255

0-1.56

1.96-3.14
3.53-4.71
5.10-6.67
7.06-8.24
8.63-9.80
10.2-11.4
11.8-13.3
13.7-14.9
15.3-16.5
16.9-18.0
18.4-20.0

20.4-21.6
22.0-23.1
23.5-24.7
25.1-26.7
27.0-28.2
28.6-29.8
30.2-31.8
32.2-33.3

33.7-34.9
35.3-36.5
36.9-38.4
38.8-40.0
40.4-41.6
42.0-43.1
43.5-45.1
45.5-46.7
47.1-48.2
48.6-49.8
50.2-74.9

75.3-100

White
White+Red
Red
Red+Orange
Orange
Aquamarine

AquGreen

Green
Green+Light Green
Light Green
Light Green+Lavender

Lavender
LPink
Pink
Pink+Yellow
Yellow
Magenta

Magenta
Cyan

Cyan
Cyan+CTO2
CTO2
CTO2+CTO1
CTO1
CTO1+CTB
CTB
CTB+

Dark 

Blue

Dark Blue
Dark 

Blue+White

CCW,Fast→Slow Rotation
CW,Slow→Fast Rotation

Aquamarine

Strobe

0-3

104-107
108-157
158-207
208-212

4-103

0-1.2

40.8-42.0

42.4-61.6

62.0-81.2
81.6-83.1

1.6-40.4

Closed
Slow-Fast Strobe
Open

Open

1

2

Pulsation

 

s

low-

f

ast, 

fast

 

off

,

slow

 

open

Pulsation

 

s

low-

f

ast, 

fast

 

open

,

slow

 

off

213-251

252-255

Random Slow-Fast Strobe
Open

83.5-98.4
99.8-100

Содержание F260II PLUS

Страница 1: ...F260II PLUS Please read these user manual carefully before use E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Страница 2: ...y to ensure excellent performance and best meet your expectations and requirements Carefully read this user manual in its entirety and keep it safe for future reference It is essential to know the inf...

Страница 3: ...object the minimum distance of the luminaire to the ammable object is 12 meters Please do not install the fixture onto combustible surface The double insulation between the LV power supply and the co...

Страница 4: ...lure if visible damage such as a crack or deep mark should be replaced The tting mounts a high pressure lamp that needs an external Immediately replace the lamp if damaged or deformed by heat The ligh...

Страница 5: ...e control lamp s swith function display light and lamp s using time automaticallay adjust cooling fan s speed Drop power when strobe lens IP20 protection IP20 Safety Devices BIPOlar circuit breaker wi...

Страница 6: ...10 20 40 30 50 Distance m ft in 2 diameter m ft in 0 17 7 0 35 1 2 0 70 2 4 1 43 4 8 1 1 3 7 1 8 5 11 916000 85130 358000 33271 79888 7425 32500 3020 18900 1757 12050 1120 8825 820 0 1 2 3 4 1 2 3 4 0...

Страница 7: ...power cord 6...

Страница 8: ...et on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety rope must be fitted This must be securely fixed to the support structure...

Страница 9: ...orking normally connection to the eiectricty mains must be carried out by a qualified electrical installer The stage lighting power supply can not be more than 3pcs pre line different types of lamps a...

Страница 10: ...9 Up arrowhead page up Down arrowhead page down Left arrowhead reduce Right arrowhead increase Enter OK function Exit in the choice screen DMX512 in out signal end out in in Display...

Страница 11: ...10...

Страница 12: ...11...

Страница 13: ...5 45 1 45 5 46 7 47 1 48 2 48 6 49 8 50 2 74 9 75 3 100 White White Red Red Red Orange Orange Orange Aquamarine Aquamarine Green Green Green Light Green Light Green Light Green Lavender Lavender Lave...

Страница 14: ...obo5 Gobo6 Gobo7 Gobo2 Shake Slow Fast Speed Gobo3 Shake Slow Fast Speed Gobo4 Shake Slow Fast Speed Gobo5 Shake Slow Fast Speed Gobo6 Shake Slow Fast Speed Gobo7 Shake Slow Fast Speed Gobo8 Shake Slo...

Страница 15: ...0 100 0 255 0 255 0 255 0 255 0 255 0 255 Unused Range From fast to slow 8 prism free switch From fast to slow 8 prism 16 prism at the same time free switch 8 prism 16 prism to free switch from fast...

Страница 16: ...41 6 42 0 43 1 43 5 45 1 45 5 46 7 47 1 48 2 48 6 49 8 50 2 74 9 75 3 100 White White Red Red Red Orange Orange Orange Aquamarine Aquamarine Green Green Green Light Green Light Green Light Green Lave...

Страница 17: ...obo5 Gobo6 Gobo7 Gobo2 Shake Slow Fast Speed Gobo3 Shake Slow Fast Speed Gobo4 Shake Slow Fast Speed Gobo5 Shake Slow Fast Speed Gobo6 Shake Slow Fast Speed Gobo7 Shake Slow Fast Speed Gobo8 Shake Slo...

Страница 18: ...0 255 0 255 0 255 0 255 Unused Range From fast to slow 8 prism free switch From fast to slow 8 prism 16 prism at the same time free switch 8 prism 16 prism to free switch from fast to slow Frost Focus...

Страница 19: ...6 42 0 43 1 43 5 45 1 45 5 46 7 47 1 48 2 48 6 49 8 50 2 74 9 75 3 100 White White Red Red Red Orange Orange Orange Aquamarine Aquamarine Green Green Green Light Green Light Green Light Green Lavende...

Страница 20: ...11 Gobo12 Gobo13 Gobo14 Gobo1 Shake Slow Fast Speed Gobo9 Shake Slow Fast Speed Gobo10 Shake Slow Fast Speed Gobo11 Shake Slow Fast Speed Gobo12 Shake Slow Fast Speed Gobo13 Shake Slow Fast Speed Gobo...

Страница 21: ...ast to slow 8 prism free switch From fast to slow 8 prism 16 prism at the same time free switch 8 prism 16 prism to free switch from fast to slow Frost Focus Pan Pan Fine TILT TILT Fine From fast to s...

Страница 22: ...0VDC GND GND 380VDC x Y PX PY Fan Fan Lamp DMX BUS BUS Fan Fan Frost M12 Focus1 M3 Focus2 M4 Gobo M5 Color M6 Prism 1 M7 Prism Rot M8 Prism 2 M9 Dimmer M10 Dimmer M11 Gobo P3 Color P4 12V GND 36V Disp...

Страница 23: ...oblems should always be handle by the professional person Disconnect the power supply before maintenance the light Lamp off Please check if install the suitable lamp Please check the connection of the...

Страница 24: ...ctric circuit and communicate IC or CPU Under this condition please change the PCB board the light can t move Please check if the power supply is suitable for the light voltage data Please check the f...

Отзывы: