SCHEDULING
Provide electric power to the devices. The light lampwill turn on. Remember not to expose people to UV-C rays.
MAINTENANCE
UV LAMP
Lamp maintenance is very important because UV-C light emitted
by the source is not visible to the eye, so, although you see the
lamp ON, its germicidal effect may not be sufficient to performs
disinfection treatment.
Before reaching the lamp,
ALWAYS
switch off power supply
If UV-C lamp gets dirty (or gets dusty) clean it with a clean cloth and
alcohol, and avoid touching the glass part with hands. To check UVC
lamp life number of hours, correct product code of the spare UV lamp
please refer to table 1. The lamp, once reached the timing for replace-
ment,
must be replaced
, this operation is carried out as follows:
• Loosen the nuts on the lamp housing and let them slide
along the lamp; grab the lamp at the 2 ends and pull it in a
direction parallel to the tube.
• Repeat the steps in reverse to insert the new lamp.
TROUBLESHOOTING
UV LAMP
See MAINTENANCE.
BALLAST
All UV-STICK models are supplied with electronic ballasts which guarantees an emission of 15% more if compared with
traditional ballasts. Furthermore, lamps are not influenced by environment temperature that can goes until -20°C. Finally,
the switching on is immediate, with no starter, and for this reason lamps last longer.
To preserve the original features of original IP protection and isolation class, and to maintain all the characteristics that
guarantee a long lasting life of this product, the ballast replacement must be done by qualified technicians verified by
Light Progress. In case of necessity, please, send the device back to our facility for any kind of repairs.
If this is not possible you can order the electronic ballast for replacement (for code see Table 1).
USE
PROTECTIVE
GLOVES
WEAR
PROTECTIVE
GLASSES