background image

LIGHT PROGRESS

 

DIRECT-H-NX [Eng.]

 

Rev. 3 Eng. Oct 2020 

Pag. 10/16

 

 

 
 

 

 

MAINTENANCE

 

 

 

UV LAMP

 

USE 

PROTECTIVE 

GLOVES 

WEAR 

PROTECTIVE 

GLASSES 

 

 

 

Lamp  maintenance  is  very  important  because  the  UV-C  light 

emitted by the source is not visible to the eye, so, although you 

see  the  lamp  ON,  its  germicidal  effect  may  not  be  sufficient  to 

perform disinfection treatment. 

 

 

Before reaching the lamp, 

ALWAYS

 switch off at the power supply. 

 

If the UV-C lamp gets dirty (or dusty) clean it with a clean cloth and 

alcohol. Avoid touching the glass part with hands. To check UVC lamp 

life  (number  of  hours),  of  the  spare  UV  lamp  please  refer  to  table 

1(correct product code required). The lamp, once it has reached the 

timing for replacement, 

must be replaced

, this operation is carried out 

as follows: 

•  Loosen the nuts on the lamp housing and let them slide along 

the lamp; grab the lamp at the 2 ends and pull it in a direction 

parallel to the lamp. 

 

 

Repeat the steps in reverse to insert the new lamp

 

 

 

 
 

TROUBLESHOOTING

 

 

UV LAMP

 

 

See MAINTENANCE. 

 

BALLAST

 

 

All  UV-FLOW models  are  supplied with  electronic ballasts  which guarantees an  emission of  15%  more  if  compared 

with  traditional  ballasts.  Furthermore,  lamps  are  not  influenced  by  environment  temperature  (<-20°C).  Finally,  the 

switching on is immediate with no starter. For this reason, lamps last longer. 

To preserve the original features of original IP protection and isolation class, and to maintain all the characteristics that 

guarantee the lasting of this product, the ballast replacement must be done by  qualified technicians  verified by  Light 

Progress.  In case of necessity, please, send the device back to our facility for any kind of repairs. 

If this is not possible you can order the entire supply channel for replacement (for code see Table 1).

 

 

 

Содержание UV-DIRECT NX Series

Страница 1: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 1 16 INSTRUCTION UV DIRECT NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H H NX UV DIRECT E75H H NX...

Страница 2: ...ance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper re...

Страница 3: ...ction manual must be preserved and must always be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not...

Страница 4: ...ly prior to the entry of the operators to allow entry in a freshly disinfected site Operation can also be managed by means of appropriate power units that especially in case of installation of various...

Страница 5: ...ackaging and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occu...

Страница 6: ...its should be carried out so as to distribute them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on t...

Страница 7: ...ss steel brackets supplied anchoring them to the ceiling by screw anchors 8 to 10 mm or by self tapping screws not supplied After inserting the anchors onto the ceiling you should tighten by supplied...

Страница 8: ...spersed ELECTRICAL CONNECTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that th...

Страница 9: ...PV Multi pole plug and socket Wire Meaning Black wire for LED terminal n 1 Wire n 1 1 anode LED for synoptic 2 cathode LED MASTER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase...

Страница 10: ...s on the lamp housing and let them slide along the lamp grab the lamp at the 2 ends and pull it in a direction parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING U...

Страница 11: ...T Code n 1 EB 55P n 1 EB 55P continuous operation Selective UV C lamp at 253 7 nm with high efficiency lighting Body in Stainless Steel AISI 304 All the used materials are tested for resistance to int...

Страница 12: ...rogress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personnel F...

Страница 13: ...ese instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits component parts lists instructions for...

Страница 14: ...f Machinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1...

Страница 15: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 15 16 Notes...

Страница 16: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 16 16...

Страница 17: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 17 16...

Отзывы: