6. DMX Address Setting 

 

When being used in conjunction with a DMX controller, each fixture must be set a specific starting address. When 

receiving signal, fixture will receive channel control signals of this address from the DMX controller. 

 

For simplicity, the user can use the same address for multiple fixtures but this will result in each fixture providing 

exactly the same output and fixtures with the same DMX address cannot be individually controlled. 

 

To control each fixture individually via DMX, each fixture must have its own unique DMX address. As this fixture 

uses 7 DMX channels, each address must be at least 7 apart.   

 

So for example – assuming the first fixture is DMX channel 1, the second fixture would need to be on channel 8, 

then the 3

rd

 channel 15 and so on. Some DMX controllers may group fixtures in lots of 16 channels – so in that case, 

fixture 1 on channel 1, fixture 2 on channel 17, 3 on 33, and so on. Refer to your DMX controllers’ instruction 

manual on how best to manage your DMX channel allocation. 

 

7. DMX-512 connection with DMX terminator 

 

 

A DMX terminator helps to reduce ‘noise’ on the DMX chain, and makes the light respond to control more 

accurately. It should be plugged in to the last fixture in any chain. For Terminator connections please see below: 

 

8. Cleaning and maintenance 

 

From time to time it is recommended the product is cleaned to ensure maximum light output and performance. Use 

a wet cloth to clean the housing as well as the lenses. Do not use alcohol based cleaners and solvents as they will 

cause damage to the product. 

 

When used in a fixed long term installation such as a venue or club, the unit should be periodically taken down from 

the installation and professionally cleaned. Dust build-up within the unit can cause damage and ultimately failure of 

components. 

 

 

9. Warranty 

 

This product is warranted for 12 months from your purchase date. We are confident that this product will give many 

years of trouble-free operation but should an unlikely problem arise, warranty claims must be via the original place 

of purchase, together with the original purchase receipt. Please keep both your original purchase receipt and this 

Содержание VIVID0312

Страница 1: ... User s instruction manual This manual contains important information about the safe installation and use of this product Please read this instruction manual carefully before installing or operating Please keep these instructions in a safe place for future reference V1 02 ...

Страница 2: ... Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the sticker of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in ...

Страница 3: ...y intended to be used as an LED lighting effect for entertainment and display applications Due to our ongoing commitment to constantly reviewing and improving products features and specifications are subject to change without prior notice LEDs 12 x 3W RGB 3 in 1 LEDs with average 50000 hours lifespan Control DMX Sound Activation Stand Alone Master Slave DMX Channels 7 Beam angle 250 3 pin XLR male...

Страница 4: ...nce to the next function You then use the button to vary the feature or program In some functions pressing enter will result in the last two digits flashing which allows you to set the speed or the response of the program using the same buttons Pressing enter again when the last two digits are flashing will cause them not to flash and allow you to go back to changing the program being selected Not...

Страница 5: ... slow to fast for programs chosen on Ch 1 Ch 4 0 255 Master dimmer for Ch 5 6 7 Ch 5 0 255 0 100 Red dimmer Ch 6 0 255 0 100 Green dimmer Ch 7 0 255 0 100 Blue dimmer 5 DMX 512 Control Connection Using a 3 pin XLR cable you can connect the product to a DMX controller and then to other fixtures with 3 pin XLR inputs and outputs When not using DMX multiple fixtures can be connected together and oper...

Страница 6: ... to manage your DMX channel allocation 7 DMX 512 connection with DMX terminator A DMX terminator helps to reduce noise on the DMX chain and makes the light respond to control more accurately It should be plugged in to the last fixture in any chain For Terminator connections please see below 8 Cleaning and maintenance From time to time it is recommended the product is cleaned to ensure maximum ligh...

Страница 7: ... industrygear com au Purchased from _________________________________________ Contact Details _________________________________________ Date Purchased _________________________________________ Invoice Receipt Number __________________________________ Copyright Light Emotion 2016 E OE Exclusively imported by LSW Imports and Distribution PO Box 887 Kingsgrove NSW 2208 sales lswonline com au www ligh...

Отзывы: