13
Fault
message
Description
Cause
Remedy
E50
brake error
brake does not operate
check brake and braking voltage
check 16-pole flat cable
check brake relay on the PCB
E51
inverter over-temperature
inverter temperature >68°C
reduce duty cycle / switches per hour /
load
high ambient temperature
check ambient temperature
E52
intermediate circuit voltage <342VDC
power off
wait until display turns off. Power on.
ohne
Display does not light up
24V short circuit
check 16-pole flat cable
faulty power supply
check power supply
faulty braking resistor
change braking resistor
Table 14:
Fault messages of the VFD control
www.hoistandwinch.co.uk