15
Please confirm the photocells are well connection and programmed. Please check if the door will be
automatically reversed when encountering an obstacle during door closing.
4.5.3 Canceling the photocell function:
Press ‘DOWN’ button and hold on until the LED displays ‘H’ , press ‘DOWN’ button the LED displays 11’, to
cancel this function
, press ‘SET’ to confirm. The default is close for this function.
to cancel this function. When setting is finished,
WARNING: Close the photo beam function when not utilizing photo beam sensor.
4.6 Auto close setting:
The default
setting for this function is 0 (off), so ensure this is displayed prior to pressing ‘set’ to exit this
setting with Auto Close off.
To activate, press ‘UP’ button and hold on until the LED displays ‘-’. Press ‘up’ button to increase the
auto-
close time by increments of 1 minute, the maximum time is 9 minutes. Press ‘down’ button to decrease
auto-close time in 1 minute increments. The auto-close function will be turned off when LED displays 0. Press
‘SET’ button to confirm.
NOTE
:
The auto close is only available when door is at its full open position.
The motor should now be fully operational. If any issues are faced, please revisit all
steps above in the order listed,
or study the common trouble shooting issues listed
on Page 17 of this booklet. More in depth trouble shooting is available at
www.liftawayaustralia.com.au/troubleshooting
.
Press „DOWN‟ button
Display „H‟
Press „DOWN‟ button
Display „11‟
Press „SET‟ to confirm
Press „UP‟ button
Display „-‟
Press „UP‟ or „DOWN‟ button to choose the close time
The minute from 1 to 9