background image

LifeSource Health Line (Toll-Free): 1-888-726-9966

E-8

In Canada–Auto Control Medical (Toll-Free): 1-800-461-0991

E-9

The UB-521CN provides an average blood pressure reading 

based on the total measurements stored in memory. When 

taking a measurement, the average blood pressure reading 

will appear and the number of measurements stored in 

memory will flash several times before the cuff begins 

to inflate. The average blood pressure reading will also 

appear briefly when you recall the measurements stored in 

memory.

The Pressure Rating Indicator™ is a feature 

which provides a snapshot of your blood pressure 

classification based on your measurements. 

This will let you quickly know what your blood 

pressure readings mean. Each segment of the bar 

indicator corresponds to the Seventh Report of the 

Joint National Committee (JNC7) on Prevention, 

Evaluation and Treatment of High Blood Pressure 

from the National Heart, Lung and Blood Institute 

- May 2003. For a more detailed look at this blood 

pressure classification, please refer to “Assessing 

High Blood Pressure” on page E-11.

:The indicator displays a segment, based on the current measurement, 

corresponding to the JNC7 Classification.  

NoTE: 

Due to other risk factors (e.g. diabetes, obesity, smoking, etc.) in addition to your 

blood pressure measurement, the Pressure Rating Indicator is approximate. Please consult 

with your physician for interpretation and diagnosis of your blood pressure measurements.

NoTE: 

Residents outside of the United States (e.g.. Canada and Mexico) should refer 

to the WHO Classification Table on page E-11 for assessment of their blood pressure 

measurement.

NuMBeR of MeasuReMeNTs sToRed IN MeMoRy

aVeRaGe

aBoUt prESSUrE ratinG inDiCator™

aBoUt avEraGE rEaDinG

aBoUt mEmorY

The UB-521CN automatically stores up to (90) blood pressure and pulse 

measurements in its memory. Measurements stored in memory are 

assigned an index number in the order of the newest to the oldest. The 

oldest reading displays as "n01".

To retrieve readings, follow these simple steps:

1. 

  When the display screen is blank, press and hold the 

START button. While holding down the START button, 

you will see the average reading displayed first. You 

will then see the memory index number (e.g. n04) of 

the most recent reading followed by the measurement. 

Release the START button when you see the memory 

index number.

2.

  The display will shut off automatically a few seconds 

after all of the readings are displayed. To turn off the 

monitor at any time, press the START button.

3. 

The display will shut off automatically a few seconds 

after the readings are displayed. 

 

If there are no measurements stored in memory, two 0s 

displayed vertically followed by a blinking "A00"

 

To 

clear

 the measurement history from memory, 

remove the battery from the unit and then place the 
battery back into the battery holder.

NoTE: 

Memory will be lost if batteries become low or are removed.

Содержание UB-521CN

Страница 1: ...Digital Wrist Blood Pressure Monitor Bilingual Instruction Guide MODEL UB 521CN English Français ...

Страница 2: ...ensure accurate results Do not attempt to service calibrate or repair this monitor Because your UB 521CN monitor contains delicate high precision parts avoid exposing it to extremes in temperature or humidity or to direct sunlight shock and dust A D Medical guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E 16 Clean th...

Страница 3: ... of the art LifeSource blood pressure monitor one of the most technologically advanced monitors available today Designed for ease of use and accuracy this monitor will facilitate your daily blood pressure regimen Physicians agree that daily self monitoring of blood pressure is an important step individuals can take to maintain cardiovascular health and prevent the serious consequences associated w...

Страница 4: ...kaline batteries recommended Battery Low The batteries are low when it blinks Unstable blood pressure due to excessive body movement Try the measurement again Remain very still during the measurement The systolic and diastolic values are within 10 mmHg of each other Fasten the cuff correctly and try the measurement again The pressure value did not increase during inflation Check for air leaks alon...

Страница 5: ...e monitor s cuff This monitor measures your blood pressure while the cuff is inflating TAKING YOUR BLOOD PRESSURE Tips for Blood Pressure Monitoring Relax for about 5 minutes before measurement Do not smoke or ingest caffeine at least 30 minutes prior to measurement Remove constricting clothing and place cuff on bare wrist Unless your physician recommends otherwise use left arm to measure pressure...

Страница 6: ...of blood in the arm to return to normal NoTE If you have poor blood circulation in winter especially when your hands and wrists are cold you may not get a blood pressure measurement systolic Diastolic Pulse TAKING YOUR BLOOD PRESSURE WHAT IS AN Irregular HeartBeat The UB 521CN Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs The Ir...

Страница 7: ...se consult with your physician for interpretation and diagnosis of your blood pressure measurements NoTE Residents outside of the United States e g Canada and Mexico should refer to theWHO ClassificationTable on page E 11 for assessment of their blood pressure measurement number of measurements stored in memory average About Pressure Rating Indicator About Average Reading About Memory The UB 521CN...

Страница 8: ...ormally blood pressure rises during work or play and falls to its lowest levels during sleep ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE Assessing High Blood Pressure for Adults The following standards for assessing high blood pressure without regard to age or gender have been established as a guideline Please note that other risk factors e g diabetes obesity smoking etc need to be taken into consid...

Страница 9: ...udies have shown that the detection and treatment of hypertension is improved when patients both consult their physicians and monitor their own blood pressure at home ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE Answers to Why Your Readings are Different Between Home and at the Doctor s Office Why are my readings different between home and at a doctor s office Your blood pressure readings taken in a ...

Страница 10: ...get the most out of your blood pressure monitoring These include Large Print Instruction Manuals Animated Operating Instructions for select models Additional Logbook Sheets ABOUT BLOOD PRESSURE TROUBLESHOOTING Corrective action Replace all batteries with new ones Alkaline batteries recommended Reinstall the batteries with negative and positive terminals matching those indicated in the battery comp...

Страница 11: ... g without batteries Blood pressure measurements determined by the UB 521CN are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standards Institute for electronic or automated sphygmomanometers SPECIFICATIONS Contact Information Our products are designed and manufactured using the latest scienti...

Страница 12: ......

Страница 13: ... 800 461 0991 Toll Free A specially trained representative will assist you A D Medical A division of A D Engineering Inc 1756 Automation Parkway San Jose CA 95131 1 888 726 9966 www LifeSourceOnline com Pressure Rating Indicator is a registered trademark of A D Medical and is patent pending 2009 A D Medical All rights reserved Specifications subject to change without notice Printed in China 4 09 I...