LifeSource ScaleSolver SS-7722LE Скачать руководство пользователя страница 10

© 2013 LifeSource Water Systems, Inc.                                  

10

START-UP

 

 
 

 
 
 

1. Connect a hose to the hose bib on the outlet 
of the tank. Run the hose to a drain. 

2. Slowly/partially open the supply water ball 
valve. Allow the tank to slowly fill with water. 
When a steady stream of water appears at the 
drain, close the supply valve. 

3. Open the inlet and outlet valves on the 
system. Transfer the bypass valves from 
Bypass to the Service position. Open a nearby 
faucet downstream from the ScaleSolver™ 
system to relieve any air. 

4. Check for leaks. Repair as needed. 

5. The system is now ready for service. 

Installation, Operation and Maintenance Manual

ScaleSolver    SS-7722

TM

Содержание ScaleSolver SS-7722LE

Страница 1: ...SourceWater com 2013 LifeSource Water Systems Inc Contactor s Lic CA 787179 NV 059578 Residential Version 10 17 2013 Installation Operation and Maintenance Manual ScaleSolver Residential System Chemic...

Страница 2: ...Cautions 6 Note to the Installer 6 Good Practices 7 Note to the Homeowner 8 Installation ScaleSolver Overview Introduction 9 Start Up Warranty 10 11 12 Installation Operation and Maintenance Manual Sc...

Страница 3: ...device e g sauna etc that requires protection from hard water ScaleSolver reduces or eliminates scale formation on internal and external plumbing surfaces as well as reduc ing spotting and streaking...

Страница 4: ...4 2013 LifeSource Water Systems Inc SCALESOLVER OVERVIEW Installation Operation and Maintenance Manual ScaleSolver SS 7722 TM...

Страница 5: ...caleSolver SS 7722LE is complete self contained loaded with media and ready to use A simple inlet and outlet connection is all that is required for installation Please review operating pressures tempe...

Страница 6: ...fully fluidize The system has no underbed so you can tip the system over without any fear of upsetting the media This makes transportation and installation much easier than conventional systems Just...

Страница 7: ...a rinse aid may be advised Shower doors and tiles should have reduced spotting When water evaporates off a surface small spots may be left behind These spots should be easy to remove with a damp clot...

Страница 8: ...ency we recommend changing the heating elements to a low watt density model Please insure that the watt density is specified at less than 70 watts per square inch and is compatible with the brand you...

Страница 9: ...and valves must be supported by unistrut pipe hangers or other means The tank connections cannot support the weight of the piping This photo from a multi tank system insallation shows properly suppor...

Страница 10: ...h water When a steady stream of water appears at the drain close the supply valve 3 Open the inlet and outlet valves on the system Transfer the bypass valves from Bypass to the Service position Open a...

Страница 11: ...uipment in warranty 7 Defective parts are subject to inspection by either LifeSource Water Systems Inc or any authorized representa tive before final commitment of warranty adjustment is made 8 LifeSo...

Страница 12: ..._ Installer or Dealer Contact Number _____________________________________________________________________________ We appreciate your purchase of the chemical free ScaleSolver scale control system Und...

Отзывы: