background image

CHANGING THE BATTERY

When the “       ” appears and blinks, the battery needs to be replaced. Make sure 

you use the same type of battery and proceed as follows: Remove battery compart-

ment lid. Use a non metal probe to remove battery. Insert new equivalent battery 

type (1.55V or LR41). Ensure battery is correctly positioned with the “+” facing up. 

Carefully replace the battery compartment lid. Properly dispose of the battery, keep-

ing it from small children and heat.

SWITCHING BETWEEN FAHRENHEIT & CELSIUS

1.

 

Press START button.

2.

 Wait until “L” symbol appears and °F (°C) starts flashing.

3.

 Press and hold START button until °F (°C) symbol flashes five times.

4.

 Release the START button. The thermometer is now changed to °C (°F).

5.

 The thermometer is now ready for measurement.

PRECAUTIONS

■ 

Do not drop unit or subject to shock.

■ 

Do not boil the probe. Clean the probe with isopropyl alcohol.

■ 

Do not use solvents or thinners on the unit.

■ 

Do not store the unit in direct sunlight or at high temperature.

■ 

Do not attempt to disassemble the unit except to replace the battery.

RECTAL USE

■ 

Commonly used for babies, young children or when it is difficult to take an oral 

or underarm temperature.

■ 

After placing the probe cover on the thermometer, lubricate with a water-soluble 

jelly such as K-Y Jelly

®

.

■ 

Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do 

not force the tip into the rectum if resistance is encountered.

■ 

Wash the thermometer as recommended.

■ 

Approximate measurement time is 10-15 seconds.

■ 

Once used rectally, the thermometer should not be used orally for sanitary reasons.

CLEANING INSTRUCTIONS

Wash the area extending about 2” from the tip with warm, soapy water after each 

use and dry thoroughly.

OR

Wipe the area extending about 2” from the tip with 70% isopropyl alcohol after 

each use.

NOTE:

 Do not submerse the thermometer in any liquid.

WARRANTY

A&D Medical warrants to the first retail purchaser that this digital thermometer 

is free from defects in material and workmanship for the lifetime of the original 

owner. This warranty does not cover batteries or damage resulting from improper 

handling or use. To obtain replacement product, please return the product, freight 

and insurance prepaid, together with proof of purchase and applicable shipping 

costs to LifeSource at the address below. Call the toll-free LifeSource Health Line at 

1-888-726-9966 for shipping costs and further information. At LifeSource’s option, 

the product will be replaced with a new or refurbished product of equal value. THE 

WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU 

OF ALL OTHER EXPRESS WARRANTIES. Some states may have laws which amend 

this warranty.

A&D Medical 

A division of A&D Engineering 

1555 McCandless Drive 

Milpitas, CA 95035
Toll-free LifeSource Health Line 1-888-726-9966 

www.LifeSourceOnline.com

K-Y Jelly

®

 is a registered trademark of Johnson & Johnson.

LifeSource

®

 is a registered trademark of A&D Medical.

© 2006 A&D Medical. 

Made in China

SPECIFICATIONS

RANGE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.0°C - 44.0°C 

90.0°F - 110.0°F

ACCURACY MEASUREMENT RANGE

 . . . . . . . ± 0.3°F less than 95.0°F 

± 0.2°F from 95.0°F to 107.6°F 

± 0.2°C less than 35.0°C 

± 0.1°C from 35.0°C to 42.0°C

DISPLAY

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1°F (0.1°C)

BATTERY

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . One 1.55V button size battery 

(LR41 type of equivalent)

POWER CONSUMPTION

 . . . . . . . . . . . . . . . . . . Less than or equal to 0.09mW

BATTERY LIFE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . Approximately 200 hours of  

continuous operation

DIMENSIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1 x 0.8 x 0.4”   

(12.9 x 2 x 1 cm)

WEIGHT

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approximately 13 grams  

including battery

DT705.indd   5-8

2/14/06   3:09:48 PM

Содержание dt-705

Страница 1: ...ure while they are well Normal average temperatures range from 97 F 36 1 C to 100 F 37 7 C when taken orally A rectal temperature is considered your real or core body temperature A rectal temperature is 1 F 0 5 C higher than an oral reading and an underarm temperature is 1 F 0 5 C lower than an oral reading HOW TO TAKE TEMPERATURE 1 Select oral underarm or rectal as your measurement site see follo...

Страница 2: ...2 from the tip with warm soapy water after each use and dry thoroughly OR Wipe the area extending about 2 from the tip with 70 isopropyl alcohol after each use NOTE Do not submerse the thermometer in any liquid WARRANTY A D Medical warrants to the first retail purchaser that this digital thermometer is free from defects in material and workmanship for the lifetime of the original owner This warran...

Страница 3: ...ratura varía según la persona La temperatura normal es la temperatura promedio de cada persona mientras se encuentra sano La temperatura normal promedio varía entre los 97 F 36 1 C y los 100 F 37 7 C cuando se toma en forma oral La temperatura rectal se considera la temperatura real o central del cuerpo La temperatura rectal es 1 F 0 5 C más alta que la temperatura oral y la axilar es 1 F 0 5 C má...

Страница 4: ...no debe utilizarse en forma oral por razones sanitarias INSTRUCCIONES DE LIMPIEZA Después de cada uso lave el área que se extiende a 2 pulg del extremo con agua jabonosa tibia y séquelo completamente O Limpie el área que se extiende a 2 pulg del extremo con 70 de alcohol isopropílico después de cada uso NOTA No sumerja el termómetro en ningún líquido GARANTÍA A D Medical garantiza al primer compra...

Отзывы: