BASE UNIT 

 

Front Panel                                                                                                                      Side Panel 

 

 

 

 

 

 

Rear Panel 

 

 

 

 

 

 

 

 

1. ALARM OUT SELECTOR: Set the Alarm Relay Output terminals as DC output or dry contacts when the 

relay activates. 

2. Terminal Board 

(Refer to the APPENDIX A-5)

: One pair of Alarm Relay output, +12VDC (12~15V   

/300mA max.) output and ground terminal, three wire sensor inputs, two Aux. outputs. 

3. COM1 

(Refer to the APPENDIX A-2, A-3)

: Communication port for USB/RS-232 Adaptor, Ethernet 

Adaptor and Data Communication Module. 

4. COM2 

(Refer to the APPENDIX A-4, A-6)

: Communication port for Relay Module (XRM-01)/X-10 

Power Line Interface Controller and GSM Module. 

5. AUX Audio 

(Refer to the APPENDIX A-6)

: Audio I/O for GSM module (GSM Module is optional). 

 

Key Board & Status Display 

 

         

 

 

 

 

 

                       

 

                                                                                                 

 

 

 

Emergency Buttons 

Speaker 

LCD Display 

Key Board 

LED status

Speaker Volume Control 

To trigger the Emergency help, 
press both buttons simultaneously.

Microphone 

Power adaptor I/P 

2. Terminal Board   

Telephone Line I/P 

Phone Set Connector

Wire Duct

1.ALARM OUT SELECTOR

3.COM1 

4.COM2

Key 

5

 & message in reading 

(Refer to A-1)

YES 

FUNC / ESC 

NO 

Key 

D

DISARM

 &

 ENTER

 

Key

 1

 & Hands-free Telephone

Key

 2

 & Switch Control 

Key

 3

 & Alarm Relay Control

Key 

4

 & Door Open (Reserved)

Key 

A

 &

 AWAY ARM

 

Key 

B

 & 

HOME ARM

 

Key 

C

,

 STATUS CLEAR

 & 

PAUSE

3

5.AUX. Audio 

Содержание LS-30

Страница 1: ...L Li if fe eS SO OS S THE ADVANCED SECURITY AUTOMATION SYSTEM FOR YOUR HOME BUSINESS Model LS 30 OPERATION MANUAL V5 20...

Страница 2: ...4 Set Device 28 4 4 1 Change Device Setting 29 4 5 Set Siren 31 4 6 Set Misc 32 4 7 Set GSM 33 5 CMS Mode 34 SPECIFICATIONS 35 APPENDIX 36 A 1 In coming Message Display A 2 Connection Diagram for USB...

Страница 3: ...INTRODUCTION INSTALLATION 1...

Страница 4: ...specific needs Simply call your local dealer trained professionals can answer any questions you have regarding additional accessories Main Features Smart Home System with Security Environment monitori...

Страница 5: ...for Relay Module XRM 01 X 10 Power Line Interface Controller and GSM Module 5 AUX Audio Refer to the APPENDIX A 6 Audio I O for GSM module GSM Module is optional Key Board Status Display Emergency But...

Страница 6: ...are divided into five main categories 1 32 Controller Panic Devices C Remote Controller Keypad Card Reader 2 128 Burglary Sensors Sirens B Door Magnet PIR Passive Infrared Glass Break Detector Vibrati...

Страница 7: ...4 7 Set GSM b Record voice message Refer to 4 3 Set Sound Record Voice c Enroll all the wireless devices by registering their ID codes in the Base Unit Refer to 4 4 Set Device Enroll Device 6 Set oth...

Страница 8: ...SSI Receiving Signal Strength Indication reading on the LCD by pressing the test button on the sensors Relocate the sensors Base Unit to get the best reading dB number if necessary If the dB number is...

Страница 9: ...USER OPERATION 7...

Страница 10: ...Sub state of State A 2 Right arrow State A 3 Enter into the sub state Note Pressing FUNC ESC at any time will let you leave the current state loop Password As many as 14 passwords can be set in the s...

Страница 11: ...nto the specific operation mode directly Clear LED LCD alarm warning status reset siren and stop dialing immediately Ignore the password request Enter HOME Mode Quick Home Press the key for 2 seconds...

Страница 12: ...The Burglar sensor B numbered 01 02 issued a burglar alarm at 01 13 19 32 this event is numbered as 253 Ex 3 LCD shows Z00 11 Disarm 12 22 08 00 03 The Master user number 1 enters the Base Unit Z into...

Страница 13: ...rent telephone numbers Reading the Telephone Number Display If the telephone number is over 16 digits it will be divided into two parts to be shown on the screen use the key to check the lower part of...

Страница 14: ...heck By Sequence Medical Button Check By Zone Number Special Sensor Check the current status of all the devices using the and keys to scroll up and down the number Reading the Device Status Display Ex...

Страница 15: ...oorbell sound Ding Dong when receiving a triggering signal from a Burglar sensor with its Bell ON OFF status set in the ON state Bell OFF No doorbell chime will sound Note The Bell function only works...

Страница 16: ...The Base Unit can t communicate with the RS 232 USB Adaptor Data Communication Module and Ethernet Adaptor Set Switch Default X 10 type X 10 Type House Code A P default A This code should be the same...

Страница 17: ...ose burglar sensors with their Enable State Home Mode Active will still be on alert and offer the protection you need while at home Refer to 4 4 1 Installer Mode Set Device Change Device Setting Burgl...

Страница 18: ...rs Besides CMS Voice message on telephone Voice on Base Unit Siren Status Burglar PIR Door Magnet Glass Break Detector Vibration Sensor GSMSMS1 5 Pager Burglar Common 1 4 GSM Voice1 5 Burglar Common S...

Страница 19: ...ts immediately stop any further dialing stop siren Press 1 LS 30 disconnects immediately and dials the next number stop siren Press 3 Enter into speak only mode The microphone on the LS 30 is disabled...

Страница 20: ...fter the password has been recognized the LS 30 will enter into monitoring mode for 30 seconds and then after two beeps the system will enter into 2 way hands free speaker phone automatically Ten 10 s...

Страница 21: ...INSTALLER CMS SETTINGS 19...

Страница 22: ...4 Installer Mode Set Timer 4 1 Set Telephone 4 2 Set Sound 4 3 Set Device 4 4 Set Siren 4 5 Set Misc 4 6 Set GSM 4 7 4 1 Set Timer Set Entry Delay Set Exit Delay Set Inner Siren Time Set Relay Action...

Страница 23: ...econds to leave the house set Exit Delay 30s Disarm Exit Delay AWAY ARM effective System status 0 255 seconds Set AWAY mode This Delay only works on the Controller with its Delay ON OFF setting in ON...

Страница 24: ...e proper Tone or Pulse mode for the auto dialer Auto Answer Ring Count Auto Answer ON with Ring Count 1 30 Auto Answer OFF default Auto Answer OFF Auto Answer ON The Base Unit will answer the incoming...

Страница 25: ...Mode 30 Minutes CMS Report OK default 30 Minutes 30 Minutes The auto dialer stops dialing after 30 minutes or after all the telephone numbers have been dialed 5 times without a successful connection C...

Страница 26: ...will be dialed only when the LS 30 is triggered by the specified alarm For example the fire number will be dialed only in a fire alarm Latchkey number Power status report number This number will be di...

Страница 27: ...uence for Alarm Report CMS1 PSTN GSM Number CMS2 PSTN GSM Number GSM1 SMS GSM5 SMS Pager Specific alarm number 1st to 4th Common numbers GSM1 Voice GSM5 Voice If there is any number that cannot be con...

Страница 28: ...your name address and telephone number Ex This is I live at phone number is Panic Segment 4 seconds The voice to be played during a Panic alarm Ex Break in Break in Calling for emergency help Burglar...

Страница 29: ...end of the delay time Refer to 4 1 Set Timer Entry Delay Entry Delay Beep OFF No beeps during the Entry Delay interval Alarm Warning ON OFF default OFF Alarm Warning ON The Base Unit generates Dong s...

Страница 30: ...nsors ID code in the initial system setup Each sensor has a unique ID that is preset at the factory 60 seconds for Device Enroll After initiating the Enroll Device procedure there is a 60 second time...

Страница 31: ...de Active Inactive PIR default Inactive Magnet default Active For Burglar sensor Home Mode Active This Burglar sensor will trigger an alarm in Home Mode operation Home Mode Inactive This Burglar senso...

Страница 32: ...sensor Supervision OFF System will not check the heartbeat signal from this sensor Type Alarm Control default Type Alarm For Special Sensors To assign the Special Sensor as an Alarm Device or a Contr...

Страница 33: ...rens will keep silent when the operation mode changes Tamper Siren In Disarm ON OFF default OFF Tamper Switch There is a Tamper Switch in the Base Unit please refer to Attach the Base Unit to the wall...

Страница 34: ...as been detected in 12 hours 2 If no activity has been detected during this time from any Inactivity Sensor Refer to 4 4 1 Change Device Setting Burglar Sensor Enable State Inactivity the system will...

Страница 35: ...refer to 4 2 1 is blank or the connection failed GSM ID This can be the mobile phone number of the SIM card of the GSM module when you buy the service from your GSM system provider you will receive a...

Страница 36: ...h a digital receiver using Contact ID and has 2 way voice capability DTMF Data Time 50ms 100ms for PSTN report default 50ms For PSTN Select the DTMF data pulse time as 50ms or 100ms for the Contact ID...

Страница 37: ...Back up Time Min 3 months after power break Battery Back Up Operation Time about 15 26 hours standby depends on back up battery type only for the operation of the Base Unit Password 14 passwords each...

Страница 38: ...te and are not allowed in the message A 2 Connection Diagram for USB or RS 232 Computer Interface COM1 cable USB or RS 232 Adaptor HyperSecureLink Software To PC USB or COM Port To LS 30 COM1 Note For...

Страница 39: ...utput represents the status of system operation mode In the ARM mode AWAY HOME this output will send out 5V voltage protected by a serial 2k ohms resistor to this terminal The user can connect a LED d...

Страница 40: ...tection function should be disabled Refer to 4 2 Set Telephone Set Telephone Line Cut Detection Permanent Off otherwise the LS 30 will trigger the line cut detection alarm when the TAM or Fax has take...

Страница 41: ...Device List Item Device Name Zone No xx xx Location User Name Initial Date of Battery 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Отзывы: