background image

INSTALLATION

6

bE AWARE:

Damage caused by inadequate or improper foundation support is not covered by the spa warranty. 

It is the sole responsibility of the spa owner to provide a proper foundation for the spa.
Make sure the foundation where the spa is placed drains water away from the spa. Proper 

drainage will keep components dry from rain and wet weather.
Your spa weight must always be considered when installing your spa.  If you are installing it on an 

elevated wood deck or other structure, it is advisable to consult a structural engineer or contractor 

to ensure the structure will support the weight.

IT IS STRONgLY RECOMMENDED THAT A qUALIFIED, LICENSED CONTRACTOR 

PREPARE THE FOUNDATION FOR YOUR SPA. 

 

A reinforced concrete pad at least four inches thick is recommended for your spa. The reinforcing 

rod or mesh in the pad should be attached to a bond wire.

iNDOOR iNSTALLATiON:

Be aware of some special requirements if you place your spa indoors. Water will accumulate 

around the spa, so flooring materials must provide a good grip when wet. Proper drainage is 

essential to prevent a build-up of water around the spa. When building a new room for the spa, it 

is recommended that a floor drain be installed. The humidity will naturally increase with the spa 

installed. Water may get into woodwork and produce dryrot, mildew, or other problems. Check for 

airborne moisture’s effects on exposed wood, paper, etc. in the room. To minimize these effects, it 

is best to provide plenty of ventilation to the spa area. An architect can help to determine if more 

ventilation must be installed. 

PLAciNg ThE SPA

chEck ThE DiMENSiONS OF YOUR SPA:

Compare the spa dimensions to the width of gates, sidewalks, and doorways along the delivery 

route used to bring the spa into your yard. It may be necessary for you to remove a gate or 

partially remove a fence in order to provide an unobstructed passageway to the installation 

location. Also, keep in mind—if you are using special equipment to place your spa into an area it 

will be necessary to include those measurements and weights. 

PLANNiNg A DELiVERY ROUTE:

Check the width of gates, doors and sidewalks to make sure your spa will pass through 

unobstructed. You may have to remove a gate or part of a fence to allow for adequate width 

clearance. If the delivery route will require a 90-degree turn, check the measurements at the turn 

to ensure the spa will fit. Check for protruding gas meters, water meters, A/C units, etc., on your 

home which will cause obstructions along the delivery path to your yard. Check for low roof eaves, 

over hanging branches or rain gutters that could be an obstruction to overhead clearances.

SPEciAL ciRcUMSTANcES:

The use of a crane for delivery and installation is primarily to avoid injury to your spa, your 

property or to delivery personnel. Our customer service may be able to assist you with the 

arrangements. Cranes are not considered “normal delivery”.

Содержание LS100DX

Страница 1: ...LS100DX LS600DX OWNER S MANUAL 110V 230V Models...

Страница 2: ...h Height Dry Weight Electrical Specs 60Hz LS100DX 4 person 5 2 5 10 34 270 lbs 110V 9a LS200DX 4 person 6 5 5 6 29 244 lbs 110V 9a LS350DX 5 person 6 0 6 9 34 351 LBS 110V 9a LS400DX 5 person 6 3 6 3...

Страница 3: ...ter Cycles 13 Operational Modes 13 SMART WINTER MODE 13 Diagnostic LCD Message 14 component operation Spacomponent operation 15 Fill Up and Start up instructions FILLING THE SpaWITH WATER 16 applying...

Страница 4: ...hildren are careful when entering or exiting the spa DON T Allow children to climb onto the spa cover Allow children to have unsupervised access to the spa Avoiding the risk of electrocution Risk of e...

Страница 5: ...ore each use of the spa and with the unit operating push the TEST button on the breaker The switch should click over to the Trip position Wait 30 seconds and reset the GFCI breaker by switching it com...

Страница 6: ...spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components Increased side effects of medication The use of drugs alcohol or medication before or duri...

Страница 7: ...re with an accurate thermometer Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN A SAFETY SIGN in the owner s package The sign which is required as a condi...

Страница 8: ...change clothes or a house entry near the spa is convenient A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide...

Страница 9: ...rborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect can help to determine if more ventila...

Страница 10: ...ment Remove 1 vertical slat and 3 screws on each side of Equipment Access Panel Door Remove 6 screws from Equipment Access Panel Door to remove door Remove screws from Black ABS Door if your spa has v...

Страница 11: ...re and attach it to the grounding lug on the power pack located in the equipment compartment 2 Only a licensed electrician may install power to the spa 3 Power supply installation must include a suita...

Страница 12: ...HN copper core wire only All wiring must be copper to ensure adequate connections Do not use aluminum wire CAUTION WARNING SHOCK HAZARD No User Serviceable Parts Do not attempt to service any electron...

Страница 13: ...t Installation permanently connected The LS600DX requires a 230 volts 32 amp service 2 hot wires a neutral wire and a ground wire When the spa is powered up the heater will provide approximately 4000...

Страница 14: ...dicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goes HERE 230V Wiring Instruction...

Страница 15: ...600DX model firmly press the Jets button once to activate the low speed of the pump and again for the high speed Firmly press the Jets button again to turn off the pump If left running the low or high...

Страница 16: ...F To enter the programming screen and toggle between Standard and Economy Mode the following is required 1 Press and hold the Light button for 5 seconds 2 Press the Light button several times until E...

Страница 17: ...ater to cool down to a lower temperature Call your dealer or service supplier if problem persists UPL No low level configuration software has been installed into the system Call your dealer or service...

Страница 18: ...ill increase or decrease the effects of any jets not in the closed position OZONE GENERATOR The ozone system greatly enhances the quality of the spa water when used to supplement the spa owner s regul...

Страница 19: ...uce the amount of water you normally have in the spa To prevent the water from hitting your topside control or flowing over the top edge of the spa Additionally failure to keep enough water in your sp...

Страница 20: ...CALCIUM HARDNESS It is important to bring the calcium reading between 100 250 PPM If the reading requires adjustment it should now be corrected If the water is too soft a low reading calcium hardness...

Страница 21: ...g it out of the spa requires many turns Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying water to remove all dirt and debris possible Let filter dry and look for ca...

Страница 22: ...f the foam inserts This will not be covered under warranty CABINET CARE Little maintenance is required to keep your spa cabinet looking good Spa cabinet product should be cleaned as needed to remove d...

Страница 23: ...Water left in the lines might freeze and damage the lines and jets 1 It will be necessary to remove all water from the interior plumbing 2 Remove the floating weir basket and filter cartridge Clean t...

Страница 24: ...ove the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position turn counterclockwise WATER IS TOO HOT 1 Check desired temperature on topside control...

Страница 25: ...ck LS600DX 303532 EQUIPMENT PACK LS100DX LS450DX 303046 3 0 hp PUMP LS600DX 230V 2SPD 303001 1 0 hp PUMP LS100DX LS450DX 115V 2SPD 303535 4 BUTTON TOPSIDE CONTROL PANEL 303298 ROUND FILTER WEIR 303299...

Страница 26: ...23...

Страница 27: ...24...

Страница 28: ...Part 303557 14 Rev D 6 14...

Отзывы: