Cautions 

Phenomenon

No indicator light

Fail activation

Reason

Low battery

interference

No account

Activate too many products 

at the same time

Weak signal to the server

Methods

Recharging

Keep closer to the bridge

Fail data uploading

Product can not 

be recharged

Fail display on weekly 

target and led

Out of transmitting range

Increasing steps are less than 100

Network error

Sync the pedometer with the server

Manually input the data

Error of usb plug

Wrongly put the pedometer 

into the charger base

Make it more than 100

Move the products towards to 

the bridge. Data can be transmitted 

in 30m without barrier.

Check network status

Log on the health care system

Change usb plug

Re- put it as instruction

Check connection between 

the bridge and pedometer

Log on www.lifesense.com 

for setting

Do it one by one

Check network status

Содержание LS401-E

Страница 1: ...LS401 E...

Страница 2: ...1 Install the bridge Please refer to the bridge instruction manual If already install the bridge skip the steps 2 Register the account and add the members 1 Please enter into www lifesense com make t...

Страница 3: ...2 Register the family account 3 RAdd a family member...

Страница 4: ...4 Select program 3 Add the device 1 Click the device and add the device...

Страница 5: ...2 Input the serial No 3 Add the user...

Страница 6: ...4 Activate the device 5 wait for activation...

Страница 7: ...dometer into the charging plate 2 Charging with the usb cable linked to the pc It finishes in around 1 5 hours and shows all the indicator lights 4 Battery charging Successfully add The page will be a...

Страница 8: ...r away from the bridge 2 Long press the button for 5 sec 3 Successfully activated after it shows you 6 green indicator lights 5 Product s activation 1 Measurement and data sending 1 Log in health care...

Страница 9: ...ck how many step you finished Attention if you change an user please long press activation button 2 Measure your step wherever you want 3 Automatically transmit the data to the server when the pedomet...

Страница 10: ...he orange indication light How many red lights you see means how much power the blood pressure monitor has 4 orange lights are on and the fifth is flickering it means you finish 4 7 for the weekly tas...

Страница 11: ...oduct if you are not professional Put the product where it is dry and cool Put the product on a level table when you don t use it Don t disassemble the product after you abandon it and obey city s rul...

Страница 12: ...1 Use tissue to clean the dirt on the pedometer 2 Dry the pedometer after clean it with soaped wiping Clean...

Страница 13: ...itting range Increasing steps are less than 100 Network error Sync the pedometer with the server Manually input the data Error of usb plug Wrongly put the pedometer into the charger base Make it more...

Страница 14: ...city Transmitting range Dimension 13 days once recharging Data of 30 days 30 meters in open place 60x44 7x11 3mm Pedometer LS401 E Working Condition Storage and Transportation Condition Temperature 0...

Страница 15: ...talled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Отзывы:

Похожие инструкции для LS401-E