Headphone Jack Connector
Tools Required:
• Phillips screwdriver
• Flat head screwdriver
• ESD (Electrostatic Discharge) grounding strap
Time:
15 minutes
Disconnect Power Source
Unplug power cord from power outlet.
WARNING: Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
NOTICE: Component damage.
Wear an ESD grounding strap during this procedure. Connect ESD grounding strap to frame bolts or unpainted metal
of frame. If ESD grounding strap is not available, touch frame bolts or unpainted metal of frame before handling any
electronics.
Remove Console from Unit
1.
Remove console from unit using a Phillips screwdriver.
2.
Disconnect base to console connections.
Remove USB / Headphone Panel
1.
Insert a flat head screwdriver into the slot between the USB / headphone panel and rear cover.
Item
Description
Qty
1
Rear cover
1
2
Slot
1
3
USB / headphone panel
1