Maintenance
MAINTENANCE SCHEDULE
PROCEDURE
TIME
Engine Oil Check
Each Use
Replace Engine Oil
After Each 40 Hours of Use (For Initial Break
in – After First (1
st
) 10 Hours of Use
Air Cleaner Filter Check
Each Use
Air Cleaner Filter
Replacement
When Needed or After Every 100 Hours of
Use
Air Cleaner Wash
When Needed
Spark Plug
Valve Clearance
Check & Re-‐adjust annually or after 300
Hours of Use
Fuel Tank
Replace Every 3 Years Based on Condition
NOTE:
Refer to Following Procedures for Proper Method to Perform Maintenance
OIL CHANGE PROCEDURES:
Refer to Controls and Feature section for diagram.
Periodic Maintenance of your engine oil should be performed after each 40 hours of
use of you Power Equipment Product. Check your engine oil level prior to each use.
1.
Start your engine and let it warm up to get the oil warm and thinner. Turn the
engine On/OFF switch to the “OFF” position. Turn Fuel Valve to the “OFF”
position.
2.
Remove the oil cap/dipstick by turning counter clockwise. Remove the oil drain
plug located below the oil cap/dipstick utilizing the appropriate tools.
USE CAUTION: THE OIL MAY BE HOT.
3.
Drain the engine oil into an approved receptacle and discard in accordance with
all Federal and State Regulations. Never dump the used engine oil on the ground
or into drains, only discard in an approved manner. Check with your local
authorities to determine the regulations in your area.
WARNING! AVOID SPLASHING OF HOT OIL; IT CAN BURN YOU AND CAUSE
SEVERE INJURY.
4.
After oil is completely drained, replace oil drain plug and tighten with
appropriate tools. Replace oil with the proper oil for your product. Refer to the
Pre-‐Operating Instruction: Generator Setup section for exact fill requirements.