LIFAN	 Power USA LF1.5HWP Скачать руководство пользователя страница 19

   

LIFAN   Power   USA   

2205   Industrial   Park   Road   

Van   Buren,   AR   72956   

866-­‐471-­‐7464   

www.lifanpowerusa.com   

19   

Transporting   and   Storing   the   Unit

   

   

CAUTION:

      

 

To   avoid   fire,   allow   water   pump   to   cool   down   for   at   least   twenty   (20)   
minutes   before   transporting   or   storing   the   unit.   

 

Always   transport   and   store   the   unit   with   the   fuel   cock   in   the   “OFF”   
position.         

 

Always   keep   unit   in   horizontal   position   to   the   ground   to   prevent   fuel   
from   spilling.      Spilled   gasoline   and   gasoline   vapor   may   ignite.   

 

Gasoline   is   extremely   flammable   and   explosive.   
   

   

Storing   the   Water   Pump:

   

   Refer   to   the   Controls   and   Features   section   for   additional   

diagrams   and   definitions.

   

1.

 

Ensure   the   storage   site   for   the   unit   is   clean   and   dry.   

2.

 

Clean   the   inside   of   the   water   pump.   

a.

 

If   the   water   pump   was   used   to   pump   water   with   mud,   sand,   or   other   
heavy   debris:   

i.

 

Operate   water   pump   to   suck   in   fresh,   clean   water   to   wash   
inside   of   unit.      Failure   to   do   so   may   result   in   damage   to   
impeller.   

ii.

 

After   washing,   remove   water   drain   plug   and   empty   the   water   
in   the   water   pump   completely.   

iii.

 

Reinstall   the   water   drain   plug.   

Before   long   term   storage   of   your   power   equipment   product,   typically   30   
days   or   more,   perform   the   following:   

3.

 

Set   the   fuel   cock   (valve)   to   the   “OFF”   position.   

4.

 

Let   the   unit   continue   to   run   until   it   stops   itself,   burning   all   of   the   fuel   in   the   fuel   

system.   

5.

 

Turn   the   ignition   switch   to   the   “OFF”   position.   

6.

 

Drain   the   engine   oil   in   accordance   with   the   “Oil   Change   Procedures”   in   this   

Owner’s   Manual’s   Maintenance   section.      Do   NOT   re-­‐fill   with   oil   until   ready   to   use   

again.   

7.

 

Remove   the   Spark   Plug   in   accordance   with   the   “Spark   Plug   Maintenance”   in   the   

Owner’s   Manual’s   Maintenance   section.      Spray   a   lubricant,   such   as   WD40®,   into   

the   Spark   Plug   hole   to   lubricate   the   top   of   the   piston   and   walls   of   the   cylinder.      

Replace   the   Spark   Plug.   

8.

 

Pull   starter   rope   until   resistance   is   felt.      This   will   place   the   valves   in   the   closed   

position.   

   

Содержание LF1.5HWP

Страница 1: ...Manual LF1 5HWP LF1 5HWP CA LF2WP LF2WP CA LF2CCWP LF2CCWP CA LF3WP LF3WP CA LF4WP LF4WP CA PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR NEW LIFAN Power USA Water Pump CA Indicates this un...

Страница 2: ...cedures as outlined in the WARRANTY POLICY and WARRANTY REGISTRATION in the Owner s Manual For any questions visit www lifanpowerusa com or call 1 866 471 7464 3 Read the Owner s Manual prior to opera...

Страница 3: ...Controls and Features 9 PRE OPERATING INSTRUCTIONS 10 Connecting Water Inlet Hose 10 Connecting Water Outlet Hose 11 Engine Oil Level Check 12 Engine Fuel Level Check 13 Air Cleaner Element Check 14 P...

Страница 4: ...ior to operation Keep this Owner s Manual for assistance in the future such as proper maintenance schedules and tips to prolong the life and effective use of your unit If you require assistance please...

Страница 5: ...t 196cc 196cc 196cc 196cc 270cc StartingCSystem Recoil Recoil Recoil Recoil Recoil FuelCTankCCapacity 0 95 Gallons 0 95 Gallons 0 95 Gallons 0 95 Gallons 1 5858 Gallons RunCTime 2 5 hrs 2 5 hrs 2 5 hr...

Страница 6: ...t if not avoided could result in death or serious injury Hazard Symbols and Meanings WARNING Running water pump emits carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cau...

Страница 7: ...f position Repair water pump with the fuel tank empty or the fuel valve in the off position Disconnect spark plug wire before transport or service WHEN STORING FUEL OR EQUIPMENT CONTAINING FUEL Store...

Страница 8: ...blic resources code WARNING Unintentional sparking can result in fire or electrical shock WHEN TESTING FOR ENGINE SPARK Do NOT check for spark with the spark plug removed Use approved spark plug teste...

Страница 9: ...Recoil Starting Handle Pull Handle to rotate engine for starting 5 Frame 1inch round steel tubing for maximum protection 6 Engine Switch Rocker Style Set to ON position to start engine OFF position t...

Страница 10: ...ances from the water surface Suction time varies with the length of the water inlet hose The filter matching with the water pump should be mounted to the end of the water inlet hose with a hose clamp...

Страница 11: ...ter Outlet Hose Use commercially available hose hose joint and clamp A short hose with a big diameter will provide the best performance A long hose with a small diameter will increase flowing resistan...

Страница 12: ...ty using the chart below in accordance with you regional environmental temperature Engine Oil Alarm System The engine oil alarm system aides in avoiding engine damage due improper amounts of engine oi...

Страница 13: ...gnite If gasoline is spilled wipe completely dry before starting the engine Avoid repeated or sustained breathing of gasoline fumes Avoid skin contact with gasoline Keep our of reach of children and p...

Страница 14: ...of the engine To Check Air Cleaner Element 1 Remove the clip item 9 in Air Cleaner A below or the wing nut item 7 in Air Cleaner B below to remove and check the air filter element 2 For Sponge Type Ai...

Страница 15: ...ter inside the pump will cause the pump to overheat Prolonged operation of engine without water inside the pump will damage the pump gasket and impeller If water within the pump is not full shut off t...

Страница 16: ...for signs of damage oil or fuel leaks b Remove excessive dirt and or debris from the unit 2 Check Suction and Discharge Hoses a Inspect general condition of hoses to ensure hoses are in serviceable c...

Страница 17: ...3 of the way toward the UPPER position 5 Turn the engine switch to the ON position 6 Pull the recoil starting handle lightly until resistance is felt then pull briskly Do NOT allow the starter handle...

Страница 18: ...n the engine switch to the OFF position NORMAL PROCEDURE 1 Move the throttle valve lever to the LOWER position 2 Turn the engine switch to the OFF position 3 Turn the fuel cock to the OFF position 4 R...

Страница 19: ...resh clean water to wash inside of unit Failure to do so may result in damage to impeller ii After washing remove water drain plug and empty the water in the water pump completely iii Reinstall the wa...

Страница 20: ...ting and Storing the Unit continued 9 Add the recommended amount of fuel stabilizer in accordance with the amount recommended by the manufacturer of the fuel stabilizer to the unused gasoline left in...

Страница 21: ...nd let it warm up to get the oil warm and thinner Remove the dipstick Refer to Controls and Features section by turning counter clockwise Remove the oil drain plug Refer to Controls and Features secti...

Страница 22: ...R CLEANER MAINTENANCE 1 Remove the clip item 9 in Air Cleaner A below or the wing nut item 7 in Air Cleaner B below to remove and check the air filter element 2 For Sponge Type Air Filters wash with s...

Страница 23: ...TE Periodically you can get sediment or trash in your Carburetor Bowl Use the following procedures to clean 1 Turn the fuel cock valve to the OFF Position 2 Remove the carburetor bowl by removing the...

Страница 24: ...altitude carburetor main spray nozzle and re adjust the adjusting screw for idle speed For usage in regions with an altitude of over 4 527ft 1380m contact your dealer to replace the standard carbureto...

Страница 25: ...7464 or take the unit to an authorized Service Center NOTE Periodically on the initial start up or after the unit has been stored for a long period of time the float for your Low Oil Shutdown system w...

Страница 26: ...any flammable materials 4 When refueling your power equipment never smoke or refuel near any flame or ignition devices Never refuel while the unit is running If during the refueling process some fuel...

Страница 27: ...C will repair or replace at its option any part that is proven to be defective in material or workmanship under normal usage Repairs and or replacement will be made without charge for parts or labor A...

Страница 28: ...nformation in this publication is based on the latest product information available at the time of approval for printing We reserve the right to make changes at any time without notice and without inc...

Отзывы: