Lifa Hydmaster 40 is a multifunctional cleaning machine for ventilation ducts. Hydmaster
40 is especially designed for tasks that require exceptionally strong force. It is designed
for  demanding tasks  and for  rectangular  and  circular ducts.  The  special  feature  is  its
strong   motor   torque,   which   is   done   hydraulically.   Hydmaster   40   is   designed   and
manufactured according to international quality and environmental management system
ISO 9001:2008 and ISO 14001:2004

Hydmaster 40 is operated with normal electricity (single-phase current) and is notably
more   silent   than   pneumatically   operated   machines.   The   hydraulic   motor   provides   an
alternative to pneumatically operated machines that need compressors in order to work.

The machine unit use hydraulic oil in power transmission. Inside the shaft there is: carbon
fibre reinforced hoses are inside a polypropylene cover; flexible glass fibre rod keeps the
shaft in the duct so it is easy to direct in it. 

Hydmaster 40 is designed for ducts that have a diameter from D 315 mm to D 1200 mm
(12.4 – 47.25 inches) The rotating speed of the brush has a stepless speed variation from
340 to 650 rpm.

The length of the shaft is 40 m which enables the cleaning of 75 meters (246 feet) of duct
when accessed in one service hatch (access door) to both directions.
   
The most advanced model of Hydmaster 40 has a camera and a screen so it is possible to
follow  the  result/progress  of   the  cleaning  work  in  the  screen.   The  screen   also  shows
possible obstacles for example sound silencers etc.

Since   the   Hydmaster   40   has   exceptionally   strong   motor   torque   it   is   possible   to   use
oversized brushes especially in ducts getting smaller in diameter. 

Lifa Y-Gear (accessory) brings efficiency to cleaning in curves and corners of rectangular
ducts of 250 mm - 1200 mm (9.8 - 47.25 inches).
For exceptionally wide rectangular ducts Lifa 3 Brush- gear, 100 mm - 300 mm (9.84 –
11.81 inches)

4

Y-Gear (1:2 rectangular duct)

Lifa 3 Brush- Gear

Содержание Hydmaster 40

Страница 1: ...aulic motor These instructions should always be available for the personnel who use the machine Please read these instructions before operating the machine Observing and following of these instruction...

Страница 2: ...RECTIONS 3 LIFA HYDMASTER 40 4 TECHNICAL INFORMATION 5 CONSTRUCTION AND CONTROL 6 SAFETY PRECAUTIONS 7 OPERATING PRINCIPLES 9 THE USE OF THE MACHINE 10 MAINTENANCE 13 SPARE PARTS 14 PROBLEM SITUATIONS...

Страница 3: ...structure functions and safe use 4 No safety functions may be removed or disabled while the machine is being used 5 If the machine has to be installed in a way that stops or impairs the functioning of...

Страница 4: ...pylene cover flexible glass fibre rod keeps the shaft in the duct so it is easy to direct in it Hydmaster 40 is designed for ducts that have a diameter from D 315 mm to D 1200 mm 12 4 47 25 inches The...

Страница 5: ...changing switch Pneumatically operating and direction changing switches Brush Connection M12 Dimensions Height 1295 mm 51 inches Width 584 mm 23 inches Length 1118 mm 44 inches Weight 93 kg 205 lbs T...

Страница 6: ...Motor Drive 3 Safety switch for motor 4 Pneumatic pedal The change of the rotating and operating direction 5 Control of the rotating speed 6 Oil pressure meter 7 Temperature level meter 8 Tool box 6 B...

Страница 7: ...ediate contact with the machine while it is operating 3 The safety of the operator The person persons who are performing the work should use personal protection filtered mouth mask helmet earmuffs gog...

Страница 8: ...rent has to be switched off when it is not being used 7 Electrical connection Make sure that the voltage supply and the current responds to the information stated in the CE plate and the information i...

Страница 9: ...portation the machine has to be tied firmly in order to prevent any damage to the machine or people The machine should be transported used and stored in an upright position Before use make sure that a...

Страница 10: ...t the working area is cleared and there are no extra personnel Ensure that all the employees performing the work have adequate protective equipment Make sure that there is enough low pressure in the c...

Страница 11: ...mm 6420281010569 300 mm 6420281010583 400 mm 6420281010590 500 mm 6420281010606 600 mm 6420281010613 700 mm 6420281010620 800 mm 6420281010637 900 mm 6420281010644 1000 mm AGGRESSIVE NYLON BRUSH WITH...

Страница 12: ...209 Grease Duct chopper Small 350 mm adjustable for ducts 250 500 mm 6420281013010 Y Gear for rectangular ducts 200mm in height 6420281011634 LIFA 3 BRUSH GEAR SET to rotate 3 brushes at same time in...

Страница 13: ...long time after it has been unplugged from the electrical network When the voltage has permanently dropped the protective casing can be removed safely Slightly blow compressed air into the frequency...

Страница 14: ...e supply mains are attached to an electrical network with protective grounding 230V 50Hz and that the supply mains are in order b Make sure that there is voltage in the electrical network and that a f...

Страница 15: ...horized representative of the manufacturer Manufacturer does not accept responsibility for maintenance carried out by a third party A written reclamation form has to be filled out and sent with descri...

Страница 16: ...ective EMC 2004 108 EC EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS 2002 95 EC Sources for harmonized standards EMC EN 55014 E...

Отзывы:

Похожие инструкции для Hydmaster 40