7

 

 

 

17

 

 

SWD Interface 
SWD_IO 36 

IO 

Serial 

line 

data signal 

VOLmax=0.4V 
VOHmin=2.4V 
VILmin=-0.3V 
VILmax=0.6V 
VIHmin=2.1V 
VIHmax=3.3V 

This interface is 
designed to firmware 
programming. Using 
this interface to 
program firmware will 
reset the IEMI No. It 
requires UART 
Update Program to 
protect IMEI No. 
during program/ 
Update. 

SWD_CLK 37 

DI 

Serial 

line 

clock signal 

VOLmax=0.4V 
VOHmin=2.4V 

Reset Pin 
RESET 22 

DI 

Reset 

the 

module 

RPU

78k

 

VIHmax=3.3V 
VIHmin=2.1V 
VILmax=0.6V 

Internal Up-adjust

low 

voltage when active. 

Simulate I/O Interface 
RIO<1> 

AIO 

Simulation 

 

Not Active yet. Keep 
clear. 

AIO<0> 

32 

AIO 

Simulation 

 

Not Active yet. Keep 
clear. 

Network status indicate port 
NETLIGHT 27 

DO 

Network 
status 
indicator 

VOLmax=0.4V 
VOHmin=2.4V 

Not Active yet. Keep 
clear. 

ADC Interface 
ADC 33 

AI  General 

Simulation-Di
gital Signal 
transform 

 

Not Active yet. Keep 
clear. 

Main UART Communication Interface 
RXD 23 

DI  Receive 

data.

VILmax=0.6V 
VIHmin=2.1V 
VIHmax=3.3V 

Keep Voltage under 
3.0V, If not Active yet. 
Keep clear. 

TXD 24 

DO Send 

data. 

VOLmax=0.4V 
VOHmin=2.4V 

Keep Voltage under 
3.0V, If not Active yet. 
Keep clear. 

RI 34  DO 

Signal 
Indicate 

VOLmax=0.4V 
VOHmin=2.4V 

Keep Voltage under 
3.0V, If not Active yet. 
Keep clear. 

Emulation Port 
DBG_RXD 25 

DI 

Receive 

data.

VILmax=0.6V 
VIHmin=2.1V 

If not Active yet. Keep 
clear. 

All manuals and user guides at all-guides.com

Содержание NB05-01

Страница 1: ...NB05 01Module Manual All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...me NB IoT Module LTE Product Model NB05 01 Compiled by Date of Compiling 20170405 No Revision Log Revised by Checked by Version Revision Date 1 Text Document Mark Shen Weifeng V1 0 1704 25 All manuals...

Страница 3: ...pply power saving technology 9 6 4 UART Joggle 11 6 5 USIM card interface 12 6 6 RI time series state under development 13 6 7 Network Status Indication under development 13 6 8 RF Circuit Design 14 6...

Страница 4: ...ons including vehicles and personal tracking security systems wireless POS industrial PDA smart metering remote maintenance and control Smart city and more NBXX 01 module is LCC package is a SMD type...

Страница 5: ...t peripheral interface Figure 1 Module feature Illustration 5 Functions 5 1 Overview The NB IoT Module has 42 SMT pins in total this chapter below will give more information Power Supply Gate Limit In...

Страница 6: ...te Description DC characteristics Remarks VBAT 39 40 PI Main Power Module VBAT 3 1V 4 2V Vmax 4 2V Vmin 3 1V Vnorm 3 6V VDD_EXT 7 PO Provide 3 Voltage for external circuit Vnorm 3 0V IOmax 20mA If thi...

Страница 7: ...et Keep clear AIO 0 32 AIO Simulation Not Active yet Keep clear Network status indicate port NETLIGHT 27 DO Network status indicator VOLmax 0 4V VOHmin 2 4V Not Active yet Keep clear ADC Interface ADC...

Страница 8: ...t connect to any other pins Temp 6 2 Operating mode The NBXX 01 module has three modes of operation to determine the different levels of low power consumption based on usage scenarios Under normal ope...

Страница 9: ...y voltage is lo ends largely t in which th ended to p 2pf near VB erence desig s under PSM d battery po dules in diffe M as follow will apply to g techno V to 4 2 V m ower than 3 y on the pow he powe...

Страница 10: ...ow 10 1 uration of the module will e nitialization the network n etc But t t PSM mode t the TAU s automatical ollows e 4 power o automatically ce diagram off the pow an reset to a level throug 17 e T3...

Страница 11: ...bott ink with the link to the b port is trans e COM port om the COM sed to view e is 921600b TXD RXD RI GND odule DCE Main port Figure7 Se 11 1 left MCU I ports main p tom MCU bottom MC bottom MCU smi...

Страница 12: ...he USIM ose to the m possible away from th 12 1 ging serial c gn of 3 3V s 1K 1K 1K 1K e design of s supports 3 G ere is a US ard circuit is USIM card c nd availabilit M circuit desi module as po he R...

Страница 13: ...ion does not w synchronize is designed 13 1 n between t o less than slot to add SIM_CLK K on add a TV ace module sistor to res eripheral circ F is placed te und l is received e after abou can start RI...

Страница 14: ...ides an ante and the pu capacitor t better to pu pin and cha F PCB Power Max 23dBm 23dBm 14 1 nce design o ws e 13 RF Cir enna connec rpose is to p that matche ut the capac aracteristic im m 2dB m 2d...

Страница 15: ...HCP linear 7 Electrical Characteristics Reliability and Wireless Characteristics The NBXX 01 module simulates the rated voltage parameters of the voltage and the digital voltage as shown in the follow...

Страница 16: ...any Address Lierda IOT Technology Park Wenyi West Road No 1326 Hangzhou Contact Number 0571 88800000 Contact Email NBIoT_support lierda com Official Website Http www lierda com The NB05 01 module is d...

Страница 17: ...wo conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This device has been te...

Отзывы: