IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions that should be followed during
the  installation  and  maintenance  of  the  UPS  and  its  batteries.  Please  read  this
manual thoroughly before attempting to install or operate this UPS.

This  equipment  can  be  installed  and  operated  by  individuals  without  previous
training.

1.

PowerSure Personal XT models are available for 230VAC supply voltages and 
loads.  Please  verify  that  this  model  matches  your  AC  mains/  load  voltage
requirements.

2.

This  equipment  is  designed  for  Commercial/Industrial  use  only.  Liebert
Corporation  neither  recommends  nor  knowingly  sells  this  product  for  use  in
critical life support applications.

3.

The PowerSure Personal XT 230VAC models are not supplied with an input
power  lead  for  connection  to  the  mains  supply.  Use  the  input  mains  power
lead from your data processing equipment to connect the UPS to the mains
supply.  The  UPS  is  supplied  with  two  output  power  leads  with  moulded
connectors  to  connect  from  the  UPS  output  to  your  equipment.  Additional
input/output leads can be obtained from your dealer.
Also  provided  is  a  Liebert  special  interconnection  cable  for  connection  to
DB9  connector  on  the  rear  of  the  UPS  for  use  with  Liebert's  SiteNet
MultiLink® software  (see  user  manual  for  details)  DO  NOT USE  FOR
OTHER APPLICATIONS.  Store in safe place if not required at this time. 

4.

This  UPS  must  be  earthed  at  all  times  during  operation.  Connect  only  to  a
mains supply socket outlet with an earth connection. A means of disconnection of
the mains supply should be within 2  metres of the UPS. 

5.

WARNING: Output receptacles on the UPS are electrically live if the UPS is
switched  ON,  even  if  the  UPS  is  not  plugged  in  to  a  mains  supply.  The
On/Off  button  on  the  UPS  does  not  electrically  isolate  the  internal  parts. To
isolate the UPS, switch OFF the UPS first, then unplug it from the mains.

.

To  reduce  the  risk  of  electric  shock,  do  not  remove  the  cover,  as  it  has  no
user-serviceable  parts  inside.    Some  components  are  live,  even  when  AC
power is disconnected.  For service, contact a qualified technician.

.

To reduce the risk of fire, use the proper rating when replacing the fuse.

.

To prevent the risk of fire or electric shock, install the UPS in a temperature
and humidity controlled room, free of conductive contaminants.

6.

Your  total  load  earth  leakage  current  must  not  exceed  3.5  milli-amperes.
Most data processing equipment meets this requirement if you use no more
than 2 pieces of equipment. For further advice contact your dealer.

7.

The UPS relies on your building wiring overcurrent protection, which must be
rated between 10-20 amperes.

8.

When  using  the  communication  features  on  the  UPS,  ensure  the  cabling
connected  to  the  DB9  communication  port  or  the  network  connection  are
kept separated by 25mm from the power leads to the UPS input and output.

Содержание PowerSure Personal XT 1250 VA

Страница 1: ...450 700 1250 VA 230V PowerSureTM Personal XT USER MANUAL English Deutsch Fran ais Italiano Espa ol...

Страница 2: ...OR OTHER APPLICATIONS Store in safe place if not required at this time 4 This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection A...

Страница 3: ...stable cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects Follow all warning...

Страница 4: ...ovides conditioned power to microcomputers and other sensitive electronic equipment PowerSure OUTPUT Lead acid battery inside the enclosure Blei Akkumulator innerhalb des Gehause INPUT FUSE 250V 5A T...

Страница 5: ...0V 50 60Hz 4 0A 1 OUTPUT 230V 50 60Hz 700VA 420W 3 1A MADE IN CHINA Remove from Box Remove Plug from Units and replace in UPS Press ON Button Plug Units s into UPS 110 mm 0 40 C Check for Damage OUTPU...

Страница 6: ...EDs of the front panel will light up for 2 seconds The green light up continuously This indicates normal operation Note If the UPS continues to beeps or the green light is not alight even mains power...

Страница 7: ...c 1 beep every 4 sec Power failure UPS is battery mode 1 beep every sec Battery low UPS is in battery mode batteries are nearly axhausted and UPS will be shut down 1 beep every 2 sec Battery weak UPS...

Страница 8: ...n Power cord defective Please contact your dealer Plug the UPS into a working wall outlet for at least Grenn LED blinks very low battery voltage 8 hours to recharge the batteries If the problem red LE...

Страница 9: ...itter 8 AC Fail open emitter 9 AC Fail open collector The DB 9 communication port allows the status of UPS to be monitored data to be backed up computer to be switched off COMMUNICATIONS The PowerSure...

Страница 10: ...20 load 20s to shutdown Battery mode 120 load 5s to shutdown BATTERY PARAMETERS Model Number PSPXT450 230 PSPXT700 230 PSPXT1250 230 Type Valve regulated nonspillable lead acid Quantity x Voltage x 1...

Страница 11: ...ident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a ma...

Страница 12: ...han 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Service...