UL 1449 second edition clamping data
Voltage
L-N
L-G
L-L
N-G
100-120V 400 400 800 400
208V
800
800
230-277V 800 800 1500 700
347V 1200
1000
2000
1000
400-480V 1500
1500
600V
2000
2000
Liebert Active Tracking Filter System
Technical Specification
Operating Voltage Range
......................................... +/-15%
Fault Current Rating (AIC)
........................................ 200 kAIC
Operating
Frequency
Range
.................................... 47 – 63 Hz
50
EMI/RFI Attenuation:
Normal Mode .............................................. 10 kHz-500MHz 60 dB
Common Mode ........................................... 10 kHz-500MHz 50 dB
Response
Time
......................................................... <0.5 ns
Operating
Humidity
................................................... 0% to 95%
Status
Indication
....................................................... LEDs, Dry Contacts, Audible Alarm,
Surge
Counter
Certifications
............................................................. UL 1449 & 1283, CSA
Enclosure
.................................................................. NEMA 12 standard
Warranty
.................................................................... 10-Years Parts / 5-Years Labor
Optional
Equipment
.................................................. Dual Surge Counter,
Remote
Monitor
Panel
Dimensional data in inches and shipping weight in pounds
Model/Configuration
Dimensions in inches
Wt
A
B
C
D
E
F
Lbs
30A Single Phase
20.0
16.0 9.0 21.25 10.0 .44 35
30A Split or Three Phase
24.0 20.0 9.0 25.25 14.0 .44 60
60A Single Phase
20.0
16.0 9.0 21.25 10.0 .44 35
60A Split or Three Phase
24.0 20.0 9.0 25.25 14.0 .44 60
100A Single Phase
24.0
20.0 9.0 25.25 14.0 .44 60
100A Split or Three Phase
30.0 24.0 9.0 31.25 18.0 .44 80
225A Single Phase
24.0
20.0 9.0 25.25 14.0 .44 60
225A Split or Three Phase
30.0 24.0 9.0 31.25 18.0 .44 80
400A Split or Three Phase
48.0 36.0 12.0 49.25 30.0 .44 300
800A Split or Three Phase
60.0
48.0
12.0
-
-
-
530
1200A Split or Three Phase
60.0
48.0
20.0
-
-
-
750
2000A Split or Three Phase
60.0
48.0
20.0
-
-
-
950
4000A Split or Three Phase
60.0
48.0
20.0
-
-
-
1300
Nominal
Voltage Codes
120
120V
208
208V
220
220V
230
230V
240
240V
277
277V
480
480V
600
600V
Source configuration
N
1 Phase L-N 2w + gnd
L
1 Phase L-L 2w + gnd
S
Split Phase 3w + gnd
Y
3 Phase Wye 4w + gnd
D
3 Phase Delta 3w + gnd
H
3 Phase Delta Hi-leg 4w+ gnd
F__ __ __ __ __ __ __ __ - __ __
Option Code
01
LED, Form C
Contacts
03
LED, Alarm, Dual
Counters, Form C
Contacts
06
LED, Alarm, Counter,
Form C Contacts
Example Part Number:
F277Y800-03
= 277/480V, 3-Phase Wye, All Mode, 800 Amp Current Rating
LED’s, Alarm & Dual Counters, Form C Contacts
Current
Code
Current
Rating
Surge Current Capability
Per Phase
30
30A 100kA
60
60A 100kA
100
100A 150kA
225
225A 150kA
400
400A 150kA
800
800A 300kA*
1200
1200A 300kA*
2000
2000A 300kA*
4000
4000A 300kA
* 200kA is available,
add –200 to part number.
Job Name____________________________
Model# ______________________________
Date ________________________________
Qty _________________________________
Quote# ______________________________
Life Cycle Surge Testing
10kA, 20kV, IEEE Cat. C3
Unit
Per Mode (L-N/L-G/N-G)
Per Phase
100 kA
12,000/12,000/12,000
24,000
150 kA
12,000/24,000/24,000
36,000
200 kA
24,000/24,000/24,000
48,000
300 kA
24,000/48,000/48,000
72,000