MFC-202/P Technical Manual
6
Master
Transformer
Position 8
Follower
Transformer
Position 8
Follower
Transformer
Position 4
Figure 3.3
Raise Command Example (After)
3.3 Configuration
The MFC-202/P features 4 keys to access its functions. The procedure to configure any
parameter is as follows:
1. Press the
P
key to enter the parameters menu.
2. Using the
↑
and
↓
keys, choose the desired parameter.
3. Press
P
to confirm the parameter’s selection.
4. Choose the desired value with the
↑
and
↓
keys.
5. Confirm pressing
P
.
The configuration sequence can be cancelled at any time by pressing
C
.
3.4 Parameter reset
The MFC-202/P can be reset to factory settings. This procedure also resets its password
to
AAAA
. To do so, power on the device while pressing
C
.