Pump operates with 

control panel selector 

switch in Hand position 

but does not operate in 

Auto position.

Control circuits malfunctioning.

Check float level control or the alternator relay for issues.

Check control panel.

Pump runs, but does 

not turn off.

Control panel selector switch in Hand position.

Set selector switch to Auto position.

Float switch unable to move to the Pump OFF 

position due to interference with the side of 

basin or other obstruction.

Position the pump or float switch so that it has adequate 

clearance for free movement.

Control panel failure.

Check control panel.

Defective float switch.

Replace float switch.

Pump runs or hums, but 

does not pump.

Discharge is blocked or restricted.

Check the discharge line for foreign material, including 

ice if the discharge line passes through or into cold areas.

Check valve is stuck closed or installed backward. Remove check valve(s) and examine for freedom of 

operation and proper installation.

Gate or ball valve is closed.

Open gate or ball valve.

Total head (lift height) is beyond pump's 

capability.

Route piping to a lower level. If not possible, a larger 

pump may be required. Consult Liberty Pumps.

Obstructed impeller or volute.

Remove obstruction.

Pump does not deliver 

proper capacity.

Discharge valve(s) partially closed or clogged.

Check the discharge line for foreign material, including 

ice if the discharge line passes through or into cold areas.

Check valve partially clogged.

Raise liquid level up and down to clear; remove check 

valve to remove obstruction.

Total head (lift height) is beyond pump's 

capability.

Route discharge piping to a lower level. If not possible, a 

larger pump may be required. Consult Liberty Pumps.

Low liquid level.

Check liquid level.

Incorrect motor rotation.

Contact factory.

Obstruction in pump or piping.

Remove obstruction.

Motor stops and then 

restarts after short 

period but overload 

heaters in starter do not 

trip.

Pump operating on a short cycle due to basin 

being too small.

A larger basin may be required. Consult Liberty Pumps.

Water returning to basin due to leaking check 

valve.

Replace check valve.

Pump cycles too 

frequently.

Improper float switch setting. 

Adjust float switch setting.

Check valve not installed, stuck open, or leaking. Install check valve(s); remove check valve and examine 

for freedom of operation and proper installation.

Pump runs periodically 

when fixtures are not in 

use.

Check valve not installed, stuck open, or leaking. Install check valve(s); remove check valve and examine 

for freedom of operation and proper installation.

Fixtures are leaking.

Repair fixtures as required to eliminate leakage.

Table 2. Troubleshooting Matrix (continued)

Problem

Possible Cause

Corrective Action

Содержание ProVore PRG Series

Страница 1: ...www LibertyPumps com Keep this manual handy for future reference For replacement manual visit LibertyPumps com or contact Liberty Pumps at 800 543 2550 Retain dated sales receipt for warranty Serial...

Страница 2: ...ly live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m...

Страница 3: ...ho is unaware of the dangers of this pump system or has not read this manual can easily be injured by the pump system In 208 230V installations one side of the line going to the pump is always hot whe...

Страница 4: ...n one month should have cutters and impellers manually operated through the breaker panel once a month to lubricate the seals For automatic models turn off the breaker unplug the piggyback switch and...

Страница 5: ...odels Automatic models A suffix come factory equipped with a float switch mounted to the pump These models come with two cords one to the float switch and the other to the pump motor The float switch...

Страница 6: ...lumbing is below the frost line If this is not feasible remove the check valve and size the basin and or adjust pump differential to accommodate the additional backflow volume Consult Liberty Pumps fo...

Страница 7: ...on operational for more than a week It is recommended to rotate the cutter 5 10 full rotations Installation All installation and maintenance of pumps controls protection devices and general wiring sha...

Страница 8: ...k Switch Operation Single phase 208 230V pumps shall only be operated without the float switch by using the circuit breaker or panel disconnect Some products may have internal capacitors that could ca...

Страница 9: ...ers automatically voids warranty RISK OF ELECTRIC SHOCK RISK OF SERIOUS INJURY OR DEATH Table 2 Troubleshooting Matrix Problem Possible Cause Corrective Action Pump does not start Damaged power or con...

Страница 10: ...mp does not deliver proper capacity Discharge valve s partially closed or clogged Check the discharge line for foreign material including ice if the discharge line passes through or into cold areas Ch...

Страница 11: ...vity Clean the impeller cavity Repeated tripping Circuit protection underrated Check rating and replace with proper size Other appliance on same circuit Pump requires separate circuit Pump is connecte...

Страница 12: ...operated or maintained per manufacturer instructions if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been...

Отзывы: