Cabling Wiring Requirements
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
connection between send and receive
units.
HDBaseT Cabling
To ensure proper performance of the DL-SCU-RX, it is recommended that you use solid
core, shielded Category 6 F/UTP cabling at a minimum. Category 5e F/UTP may perform
well but may not support power over HDBaseT reliably over longer distances.
For optimized HDBaseT performance use the following Liberty Wire and Cable branded
cabling;
Category 6 plenum;
24-4P-P-L6SH
Category 6A plenum;
24-4P-P-L6ASH
Category 6 NON-plenum;
24-4P-L6SH
Category 6A NON -plenum;
24-4P-L6ASH
When using shielded category cabling
ALWAYS
...
....use shielded connectors
....properly ground the category cable
RS232 Wiring
Connect the display device RX signal to TX
on the DL-SCU-RX extender. Connect the
display device TX signal to RX on the DL-
SCU-RX extender.
TX RX G
RX TX G
DL-SCU-RX
RS232 PORT
DISPLAY
RS232
PINOUT
Connecting to
TV Display