Operation Of Your Rocket Heater On Fuel Pellets
The Pellet Hopper Adapter allows the Liberator RMH-2 to burn pellets without permanently
modifying the heater in any way.
Steps to Attach the Pellet Hopper Adapter
1. Install the Pellet Feed Tube on to the Pellet Hopper Adapter by inserting the tube into the
Coupler located on the bottom of the hopper.
2. Tighten the set screw (size 5/16" X 18 TPI) with the provided allen wrench.
3. Place the Pellet Hopper on top of the fuel feed tube of the Rocket Heater.
Make sure that the
hopper is well seated and centered,
and ensure that the pellet hoppers retainers (see next page)
are properly set within the tube. Make sure that the hopper always has the lid flip up from the
front with the hinge facing towards the back of the heater.
4. Open the ash cleanout door and insert the burn grate until the edge of the metal is within the
tube just enough to allow the ash cleanout door to close again, ideally as close to making
contact with the ash cleanout door as possible. Check and ensure that the Ash Cleanout Door
can be fully closed. Close the door.