LH Argo LH 1200 Скачать руководство пользователя страница 18

E

NCODING THE 

LH 1200 

LH 1200 O

PERATORS 

& F

ITTING MANUAL

 

18 

LH A

GRO

 

FLOWMETER CALIBRATION (FLOW FIGURE) 

Key 

Function 

 

Flow figure: 

 
1.  If this is the first time that the monitor is being used with a sprayer, encode a 

"start" flow figure of 2000. 

2.  It is recommended to hold still when calibrating the flow meter to avoid 

incorrect readings on the sprayer tank indicator. If there is any doubt as to the 
accuracy of the tank indication, then weighing the sprayer will give greater 
accuracy. 

3.  Fill the sprayer with min. 600 litres (the more the better) and note the amount 

filled. 

4.  Reset the litre counter as follows: 

 

Press 

 

 

 

Press the L key once then press and hold down the 0/C key until the 
litre counter is zeroed. 

 

5.  Spray minimum 500 litres. 
6.  Read the amount remaining in the tank using the tank indicator. 
7.  Calculate the consumed amount using the following formula: 

 

CONSUMPTION FROM TANK 

= Amount filled – Volume remaining in the tank

 

 

8.  Insert the consumed amount in the following formula: 

 

Old flow figure x Consumed litres 

NEW FLOW FIGURE = 

Amount displayed (litre counter) 

 
9.  Encode this new value as the new flow figure. 
 

NOTE! 

If the percentile deviation of the flow meter is known, the calibration 
figure can be altered using the +/-% key. Each time the key is pressed 
the sign will be altered. The flow figure can only be altered in whole % 
using this key. 

 

Содержание LH 1200

Страница 1: ...UAL FITTING INSTRUCTIONS FOR THE LH 1200 SPRAYER MONITOR LH No 020 122 UK Version 2 00 LH Technologies Denmark ApS M lhavevej 2 9440 Aabybro Denmark Tel 45 9696 2500 Fax 45 9696 2501 Internet http www...

Страница 2: ...LH 1200 OPERATORS FITTING MANUAL 2 LH AGRO...

Страница 3: ...RRY SPREADER 13 APPLICATION RATE MONITORING 13 SECONDARY FUNCTIONS BALER 13 UNIT COUNTER 13 SECONDARY FUNCTIONS DISTANCE MEASURING 14 ENCODING THE LH 1200 15 WORKING WIDTH 15 FORWARD SPEED CALIBRATION...

Страница 4: ...ompensation caused by for example any of the following Disturbance to from any electronic services or products that do not confirm to the standards for CE marking Missing or poor signal coverage or a...

Страница 5: ...s Description Pos Description 1 Time functions 7 Flow figure calibration 2 Forward speed 8 Flow figure encodement 3 Area trip 9 Working width encodement 4 Application rate 10 Wheel circumference encod...

Страница 6: ...odes The secondary functions are as follows Distance in metres Shaft speed RPM Fertiliser application rate Sow seed application rate Fertiliser consumption Kg counter Sow seed consumption Kg counter U...

Страница 7: ...e secondary functions can be selected as required The monitor can measure distance in metres as an extra function This function requires a special encodement code and can therefore only be used by its...

Страница 8: ...colon means that the time counter is stopped Pressing this key for min 3 seconds resets the counter FORWARD SPEED Key Function Kilometres per hour Pressing this key displays the present forward speed...

Страница 9: ...res that area is only counted when the implement is working The area trip counter counts synchronically with the area total counter NOTE This key has a different function if 8888 or 9999 are encoded a...

Страница 10: ...moving forward Correct performance presupposes correct calibration of the flow meter see page 18 Flow meter calibration should be checked at regular intervals NOTE This key has a different function i...

Страница 11: ...keys in this order Key Function RPM NOTE The L key cannot be used when this encodement is used FERTILISER DISTRIBUTOR WITH FEED ROLLER PNEUMATIC It is possible to meter the flow of fertiliser on this...

Страница 12: ...ncodement is used SEED RATE MONITORING It is possible to meter the flow of seed using a special sensor which gives a suitable number of pulses per revolution The calibration figure is determined durin...

Страница 13: ...ilable ENCODE XXXX is the known calibration figure in kg with 2 decimals 5 00 kg is encoded as 500 The application rate will be shown as m3 ha Key Function Slurry application rate Total slurry consump...

Страница 14: ...AGRO SECONDARY FUNCTIONS DISTANCE MEASURING This function can only be used alone When this function is activated all other functions are unusable ENCODE Press the shown keys in this order Key Function...

Страница 15: ...lly until another working width is encoded press any other key to leave this encodement FORWARD SPEED CALIBRATION WHEEL CIRCUMFERENCE Key Function Wheel circumference The distance in centimetres that...

Страница 16: ...umber of magnets fitted to the wheel 6 Press the wheel circumference key and an 0 appears on the left of the display indicating that wheel circumference has been selected 7 Encode the result from step...

Страница 17: ...display STOP IMMEDIATELY 4 Make a mark on the field and on the tire 5 Drive until the display changes from 10 to 11 STOP IMMEDIATELY 6 Make a mark on the field again 7 Measure the distance between th...

Страница 18: ...4 Reset the litre counter as follows Press Press the L key once then press and hold down the 0 C key until the litre counter is zeroed 5 Spray minimum 500 litres 6 Read the amount remaining in the tan...

Страница 19: ...as been emptied Clean and check the paddle wheel and shaft for wear at regular intervals VOLUME MONITORING CALIBRATION FOR SEED AND FERTILISER The LH 1200 must be encoded with some special values for...

Страница 20: ...bration figure for the machine can be calculated as follows Amount released in grams x 100 NEW CALIBRATION FIGURE FLOW FIGURE Pulses displayed on the monitor 6 Encode the calculated values as the new...

Страница 21: ...12V so that the monitor is switched on and off with the ignition ignition live The power cable wires should be connected thus Blue 12V power Brown 0V ground IMPORTANT Never incorrectly connect these w...

Страница 22: ...ram The distance between the magnets and the wheel sensor must not be greater than 5 mm Fit 2 magnets if the effective wheel circumference is larger than 200 cm NOTE The magnets must be fitted with eq...

Страница 23: ...e fitted to the cardinal shaft on 4 wheel drive machines A bipolar sensor must be used when fitting to the cardinal shaft This sensor must be ordered separately as it is different than the supplied se...

Страница 24: ...movement of minimum 50 mm The distance between the sensor and the magnet must not exceed 5 mm An electrical signal from i e a sprayer switch box etc can be used as the implement signal The signal must...

Страница 25: ...t The cable from the flow meter must always point upwards The cable length may be shortened but ensure that it will allow the tractor to turn trailed sprayers or the sprayer to be raised lowered lift...

Страница 26: ...ated low do not run therefore run the machine at full speed It is best to activate the sensor by turning slowly by hand Pos 2 r is displayed when the implement sensor is activated NOTE r is displayed...

Страница 27: ...LH 1200 OPERATORS FITTING MANUAL NOTES LH AGRO 27 NOTES...

Страница 28: ...NOTES LH 1200 OPERATORS FITTING MANUAL 28 LH AGRO...

Отзывы: