Installation Requirements
6-2
InterReach Fusion SingleStar Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
6.1.1
Component Location Requirements
Fusion SingleStar components are intended to be installed in indoor locations only.
6.1.2
Cable and Connector Requirements
Fusion SingleStar equipment operates over CATV 75 Ohm cable with F connectors.
These cables are widely-used, industry standards for the cable TV industry. The regu-
lations and guidelines for Fusion SingleStar cable installation are identical to those
specified by the TIA/EIA 568-B standard and the TIA/EIA/570-A standards.
LGC Wireless recommends solid copper center conductor, plenum-rated CATV cable
and connectors for conformity to building codes, standards, and to ensure stated per-
formance of distance and RF specifications.
Commscope 2065V cable or equivalent is required for RG-59.
Commscope 2279V cable or equivalent is required for RG-6.
Commscope 2293K cable may also be used for RG-11.
NOTE:
In order to meet FCC and CE Mark emissions requirements, the CATV
cable must be screened and it must be grounded using shielded F connectors at both
ends.
LGC Wireless recommends connectors with fixed centerpins to ensure proper seating
and to eliminage oxidation, which occurs with bare center conductors. Recommended
conductors are as follows:
• FP-C4F for commScope 2065V cable
• FP-C55A for CommScope 2279V cable
• FP-C71A for CommScope 2293K cable
6.1.3
Distance Requirements
Table 6-1 shows the distances between Unison components and related equipment.
Table 6-1
Distance Requirements
Equipment
Combination
Cable Type
Cable Length
Additional Information
Repeater/BTS to
Fusion SingleStar
Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical
Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum
Limited by CE Mark require-
ments.