Connecting Contact Alarms to a Fusion SingleStar System
6-36
InterReach Fusion SingleStar Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
6.6.2
Alarm Sense
Use AdminBrowser to enable the Fusion SingleStar system for “alarm sense” when
connecting to the contact closure of LGCell Main Hubs or other external alarms (refer
to Set Contact Sense Properties in the
AdminBrowser User Manual
).
Using Fusion SingleStar to Monitor LGCells
When you connect LGCell to Fusion SS, the Fusion SingleStar Hub is the input of the
alarms (alarm sense) and the LGCell is the output (alarm source), as shown in
Figure 6-16. The input alarm sense needs to be set to normally closed (NC).
Figure 6-16
Using Fusion SingleStar to Monitor LGCell or Unison
LGCell or Unison supports only faults. You must use the Alarm Sense Adapter Cable
(refer to page 6-38) to interface the daisy-chain cable to Fusion SS. The adapter cable
is required because it translates the LGCell fault pinout to the sense input pins on the
Fusion SingleStar Hub.
Figure 6-17
Alarm Sense Contacts
Up to 5 LGCell (Unison) Main Hubs
Fusion SingleStar Hub
Alarm
Sense
Alarm
Source
Alarm
Source
Alarm Sense
Adapter Cable
5-port Alarm Daisy-Chain Cable
8
1
Diagnostic I
External
Equipment
Contacts
+5V