background image

You can program the following registers:

Register Function

Available Factory

values

pre-set

CV1

Loco address

(00-22)

[3]

CV2

Starting voltage

(0-255)

[2]

voltage for speed setting 1 - if loco starts only at a higher 

speed setting, increase value.

CV3

Acceleration (1 = fast, 255 = slow)

(1-255)

[3]

CV4

Braking (1 = fast, 255 = slow)

(1-255)

[3]

CV5

Max. voltage

(1-255)

[255]

Voltage for highest speed step - if a lower top speed is 

desired, decrease value.

CV5 

after input of CV6 (when programming with older 55015)

function value for CV to be programmed

CV6

CV to be programmed (when programming with older 55015)

CV13

Analog function of F terminals (must be 0 at all times)

[0]

CV29

NMRA configuration 

[4]

Bit programming

Bit 1: direction, 0 = normal, 1 = reversed [0]

Bit 2: speed steps, 0 = 14 (LGB), 2 = 28 [0]

Bit 3: analog operation, 0 = not possible, 4 = possible [4]

Bit 4: not used [0]

Bit 5: speed steps, 0 = factory-programmed, 

16 = user-programmed [0]

Bit 6: address area, 0 = 0-127 (LGB), 32 = 128-10039 [0]

To program, add the values for the individual Bits and 

program the resulting function value.

Hint: To program a loco to reversed direction of travel (for 

example, F7 A-B-A combination), program function value 5.

Attention! Loco addresses 128-10039 and 28 speed steps 

cannot be used with LGB MTS).

CV49

Voltage for function terminal F1

(1-32)

[32]

(depends on loco model, do not change, as functions

can be affected or destroyed)

CV50

Voltage for lighting terminals (see CV49)

(1-32)

[5]

CV51

Command for function terminal F1

[10]

0 = lighting button 9

1 = button 1 (buttons 2-8 not used)

9 = button 1 (buttons 2-8 used as well)

10 = button 2

11 = button 3

12 = button 4

13 = button 5

14 = button 6

15 = button 7

16 = button 8

64 = lighting button 9 (on only when loco is reversing)

65 = button 1 (on only when loco is reversing)

128 = lighting button 9 (on only when loco is moving forward)

129 = button 1 (on only when loco is moving forward)

(depends on loco model, do not change, as functions

can be affected or destroyed)

CV52

Command for front lighting terminal (see CV51)

[128]

CV53

Command for rear lighting terminal (see CV51)

[64]

CV54

LGB configuration

[2]

Bit programming

Bit 1: hand-off function, 0 = off, 1 = on [0]

Bit 2: MTS Back-EMF, 0 = off, 2 = on [2]

Bit 3: analog Back-EMF, 0 = off, 4 = on [0]

Bit 4: not used [0]

Bit 5: 0 = F1 constant, 16 = F1 flashing [0]

Bit 6: 0 = F2 constant, 32 = F2 flashing [0]

Bit 7: sound function (0 or 64) [0]

Bit 8: sound function (0 or 128) [0]

To program, add the values for the individual Bits and 

program the resulting function value. The values for 

Bits 5-8 vary between locos. The values for your loco

can be read using the 55045 MTS PC Decoder Programming

Module.

Hand-off function on: When operating with 55015, you can 

adjust direction and speed for two seconds after selecting a 

moving loco without causing the loco to stop.

CV55

Reset factory pre-set values for CVs

Program:

6-55->

5-55->

CV56

Voltage for function terminal F2

(1-32)

[32]

(depends on loco model, do not change, as functions

can be affected or destroyed)

CV57

Command for function terminal F2 (see CV51)

[11]

CV58

Pause time (analog operation) (0.5 seconds x function value) (0-255)

[0]

When the polarity of the analog track voltage is reversed, the 

loco waits for the programmed time period, then accelerates

in the new direction

CV59

Half-speed mode (0 = Half-speed mode deactivated)

[4]

CV60

Back-EMF: Max. adjustment factor

(1-255)

[4]

Specifies the max. increase or decrease of voltage applied 

during each time interval (programmed in CV61)

1 = small steps, 255 = large steps

The factory pre-set values of CV60 and CV61 are optimized 

for LGB motors.

CV61

Back-EMF: Adjustment frequency

(0-255)

[16]

Specifies how often per second the motor voltage is adjusted -

accordingly, the loco will react to curves and grades 

immediately or with a short delay

0 = immediate adjustment, 255 = maximum delay

CV62

Back-EMF: Max. Adjustment

(0-255)

[255]

Limits the total adjustment in motor voltage. If there is a very 

large load on the motor, the adjustment will not exceed this 

17

16

Содержание MZS-DUO 23900

Страница 1: ...et UL et ne peuvent tre ouverts et r par s que par le fabricant Toute viola tion cet gard entra nera la perte imp rative de tous les droits de garantie et un refus de toutes r parations quelles qu el...

Страница 2: ...ieb durch mechanische Teile entstehen der sich in Teppichen und anderen Materialien festsetzt Bedenken Sie dies beim Aufbau der Gleise Bei Sch den bernimmt Ernst Paul Lehmann Patentwerk keine Haftung...

Страница 3: ...dem Fahrgestell ziehen Schraube f r das Gest nge am Treibrad mit Haftreifen l sen Gest nge abnehmen Mit einen kleinen flachen Schraubendreher den alten Haftreifen entfernen Den alten Haftreifen aus d...

Страница 4: ...Taste 5 14 Taste 6 15 Taste 7 16 Taste 8 64 Lichttaste 9 ein nur bei R ckw rtsfahrt 65 Taste 1 ein nur bei R ckw rtsfahrt 128 Lichttaste 9 ein nur bei Vorw rtsfahrt 129 Taste 1 ein nur bei Vorw rtsfah...

Страница 5: ...ammiert Programmieren mit lteren Universal Handys 55015 mit Programmiermodus P Register CV 1 bis CV 4 k nnen direkt programmiert werden indem der gew nschte Funktionswert in das betreffende Register e...

Страница 6: ...t illuminated coupler lowered 8 Half speed mode on off With a Loco Remote or Universal Remote press the numbered loco function buttons For example to lower the front coupler hook press button 2 on the...

Страница 7: ...eplace the traction tire Pry the old traction tire out of the wheel groove Gently insert the new traction tire into the wheel groove Make sure that the traction tire is seated properly in the wheel gr...

Страница 8: ...loco model do not change as functions can be affected or destroyed CV52 Command for front lighting terminal see CV51 128 CV53 Command for rear lighting terminal see CV51 64 CV54 LGB configuration 2 B...

Страница 9: ...desired function value in register CV5 Example Set hand over function to ON pro gram register CV54 to function value 3 To program Display shows P Select register CV6 press 6 Input 54 register you want...

Страница 10: ...le r duit est programm l adresse de locomotive 03 Pour des renseignements sur la fa on de pro grammer l adresse de locomotive consulter les fiches d instructions des divers l ments du syst me mul titr...