39
1. Cautions during the service
Both AC220V and DC power are embedded in the controller assembly output connector, so be careful of the
electric shock during the disorder diagnosis.(Wear cotton gloves during the work.)
When you replace controller in the washer, make sure to check if the power is cut off before the disassembly
or assembly.
Always be careful of the static electricity during the handling of the controller assembly, and transport and store
it in static electricity prevention vinyl bag.
You can check problems of the washer as follows by pressing the start/pause button.
The washer must be empty and the controls must be plugged in an
d turned off.
2. SVC test mode
How to enter SVC test mode: Power ON, press “Cold Wash” and “Wash” key at the same time to enter the
test mode.
Every time you press start/pause button, test mode changes, and you can check the operation status.
When you start the test mode, door is locked, and when the test mode ends, door opens.
3. Actions in each test mode
You can check problems of the washer as follows by pressing the start/pause button.
4-4. How to use Test Mode
Step
Mode
Action
Displayed Contents
Remark
t1
Main Version Check
All LEDs are lighted
‘Main VERSION’ and ‘Model
Option Character’
You can check ‘tE Error’
t2
Display Version check
and Button check
-
‘Display Version’
-
t3
Water
Valve
Check
A
Cold Valve is activated
Level frequency
(26.7kHz is displayed as 67)
Valve operates until
23.3kHz, and the power
is automatically turned
prevention)
B
Hot Valve is activated
C
Softner Dispenser is activated
D
Jet Spray Dispenser is activated
t4
Heater
Check
Heater On
Eye sensor correction group
value(1~26)
Heating is activated
t5
Alpha
Check
Carry out alpha
Water discharge starts
Alpha RPM
RPM : 220
On time : 180s
Slope : 30 rpm/sec
t6
Drain
Check
At water discharge level
frequency of 26.0kHz, after 50
sec., it is automatically changed
to T7.
Before the level frequency
reaching 26.0kHz, level
frequency is displayed after
reaching the longitude data.
-
t7
Load
sensing
Check
After completing spray
amount detection 1 time, it is
automatically changed to t8.
Displays spray amount detection
result value.
(Displays Err)
-
t8
Agitate
Check
Door Lock reset
Pulsator Mode change
Pulsator stirring starts
Displays spray amount detection
result value.
(Displays Err)
t9
Spin
Check
anddE
Error
Check
Basket Mode change
Spin dry starts
Before 500RPM: current RPM/
500RPM or more: UB value/
Before 500RPM: Max emission
value/
RSt: UB value
Current RPM is displayed in the
units of 2 sec.
After reaching the maximum
RPM, continuous MS
(40~90rpm) area for 200 sec.
UB No sense
t10
OFF
Power off
-
-
Copyright © 2017 LG Electronics Inc. All rights reserved.
Only training and service purposes.