WILL NOT CIRCULATE WATER
Is the impeller of the drain pump clogged?
Are the Hose Connector and/or Hose clogged?
Is the connector disconnected, disassembled?
Is the coil of the right side of drain pump open
or short circuited? (Coil R is 18-30
Ω
)
When checking voltage between the
connectors during spin, is the voltage
1
20V
AC, as the figure?
Remove foreign material.
Remove foreign material.
Reconnect or repair
the connector.
Replace PUMP MOTOR
ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY.