7. TROUBLE SHOOTING
7-1.BEFORE SVC CHECKING
■
Be careful of electric shock or disconnecting the parts while trouble shooting.
■
Voltage of each terminal in 113-127 V~ and DC while applying an electric current.
7-2.QC TEST MODE.
①
Pressing Option (Left) and Soil Level button simultaneously.
②
Press the Power button, while the above condition.
③
Press the Start/Pause button as follows.
Number of times the
Start/Pause button is pressed
7-4.HOW TO KNOW THE WATER LEVEL FREQUENCY
Press the Water Plus and Option(Left) button simultaneously.
ex) 241 : Water level frequency = 241
×
10 kHz
-1
= 24.1 kHz
The digits means water level frequency (10
-1
kHz)
s
u
t
a
t
S
y
a
l
p
s
i
D
t
n
i
o
P
k
c
e
h
C
None
Turns on all lamps and locks the door.
1 time
Tumble clockwise.
rpm (42~50)
)
5
6
~
5
5
(
m
p
r
.
n
i
p
S
d
e
e
p
s
w
o
L
s
e
m
it
2
137)
(
m
p
r
.
n
i
p
S
d
e
e
p
s
h
g
i
H
s
e
m
it
3
4 times
Inlet valve for prewash turns on.
Water level frequency (229~255)
5 times
Inlet valve for main wash turns on.
Water level frequency (229~255)
6 times
Inlet valve for hot water turns on.
Water level frequency (229~255)
7 times
Tumble counterclockwise.
rpm (42~50)
8 times
Heater turns on for 3 sec.
Water temperature
9 times
Circulation pump turns on.
Water level frequency (0 ~ 255)
10 times
Drain pump turns on.
Water level frequency (0 ~ 255)
-
ff
O
s
e
m
it
1
1
14