13
7. TROUBLE SHOOTING
7-1.BEFORE SVC CHECKING
■
Be careful of electric shock or disconnecting the parts while trouble shooting.
■
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
7-2.QC TEST MODE.
①
①
Pressing Rinse and Steam Wash button simultaneously.
②
②
Press the Power button, while the above condition.
③
③
Press the Start/Pause button as follows.
Check Point
Display Status
None
Turns on all lamps and locks the door.
1 time
Tumble clockwise.
rpm (42~50)
2 times
Low speed Spin.
rpm (55~65)
3 times
High speed Spin.
rpm (125~155)
4 times
Inlet valve for prewash turns on.
Water level frequency (25~65)
5 times
Inlet valve for main wash turns on.
Water level frequency (25~65)
6 times
Inlet valve for hot water turns on.
Water level frequency (25~65)
7 times
Inlet valve for steam turns on.
Water level frequency (25~65)
8 times
Inlet valve for bleach turns on.
Water level frequency (25~65)
9 times
Tumble counterclockwise.
rpm (42~50)
10 times
Heater turns on for 3 sec.
Water temperature
11 times
Circulation pump turns on.
Water level frequency (25~65)
12 times
Drain pump turns on.
Water level frequency (25~65)
13 times
Water level Sensor for Steam
Water level frequency of TSG(0~255)
14 times
Steam Heater turns on for 1.2 sec.
TSG temperature
15 times
Off
-
Number of times the
Start/Pause button is pressed
7-4.HOW TO KNOW THE WATER LEVEL FREQUENCY
Press the
Temp.
and
Spin
button simultaneously.
ex) 241 : Water level frequency = 241
×
10-1kHz
=24.1kHz
The digits means water level frequency (10
-1
kHz)