9
EN
How to Install the Unit
1
Measure the space for installation to assure a
good fit. The air conditioner must be installed
firmly into place to prevent vibration and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the
unit. There must be at least 50 cm (20 in.)
of cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
Fence
Awning
Heat
radiation
Cooled air
10~15 mm
Over 50 cm
Foam
70-150 cm
Level
1/4 Bubble
CAUTION
•
The external grille must be exposed outside for
air discharge.
Drain Pipe
In humid weather, excess water may cause the
base pan to overflow. To drain the water, remove
the drain cap and secure the drain pipe to the rear
hole of the base pan.
Press the drain pipe into the hole by pushing down
and away from the fins to avoid injury.
Hang
Drain Cap
Push
Drain Pipe
CAUTION
•
Be careful when inserting the drain pipe. Push
away from the sharp fin area to avoid slipping
injuring yourself.
Space for Outside Air Flow
100 mm minimum
AIR IN
AIR IN
AIR OUT
OPTION A
100 mm
100 mm
LOUVRE
FRONT
45° BRICK CUT AWAY
TO CLEAR LOUVRES
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR IN
AIR IN
BRICK
WALL
AIR OUT
TOP
VIEW
OPTION B