Operation
Feature
Insulation Resistance Test
About the jControls or the Air Conditioner
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (green or green and yellow) is to be open.
3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part
on the equipment at all positions [except Off] of the ROTARY SWITCH.
4. The value should be over 1 M
Ω
.
Operation
Operation
High
Fan
Low
Fan
High
Cool
Off
Low
Cool
Thermostat
1
2
3
4
5
6
7
8
9
Off
- Turns air conditioner off.
High Fan
- High speed fan operation without cooling.
Low Fan
- Low speed fan operation without cooling.
High Cool - Cooling with high speed fan operation.
Low Cool - Cooling with low speed fan operation.
FAN ONLY- Fan operation without cooling.
TURBO COOL - Cooling with high speed fan operation.
This automatically controls the temperature of the
indoor air.
Turn the knob so that arrow points to the larger marks
for greater cooling.
Point the arrow to the smaller marks for more moder-
ate cooling.
(i.e. the higher number, the greater cooling)
8 Room Air Conditioner
Содержание W051CA