REPLACING THE BELT AND/OR
AGITATOR
Check the belt and agitator regularity. If they are broken
of worn out, replace them.
Turn the unit over and remove the bottom plate as
described in Removing/Installing the Bottom Plate
section.
To remove the agitator, grasp both ends of the agitator
and lift it slowly. Remove the belt from the agitator pulley
and the motor shaft. If the belt is broken, be sure all
pieces are removed.
Loop the new belt around the motor shaft and agitator
pulley.
Reinsert the agitator, making sure that both ends of the
agitator fit into the grooves in the nozzle head.
After installing the agitator, turn it by hand to make sure
that the belt is not twisted or pinched and that all parts
turn freely.
Reinstall the body cover by reversing the steps in the
Removing/Installing the Bottom Plate section.
The agitator must also be cleaned according to the
following schedule:
Vacuum Use
Clean Agitator
HEAVY - (used daily)
every week
MODERATE - (used 2-3 times/week)
every week
LIGHT - (used 1time/week)
every 2 months
Replacement part are avaiable from your dealer.
REPLACEMENT INSTRUCTIONS
WARNING
Electrical Shock and Personal Injury Hazard
• Unplug the vacuum cleaner before cleaning the unit. Failure to do so could result in electrical shock or personal injury
from the vacuum cleaner starting unexpectedly.
WARNING
Personal Injury Hazard
The belt is under high tension; be careful when
removing the agitator.
Failure to do so could result in personal injury
caused by the agitator releasing quickly and
snapping away.
Agitator
Belt
End Cap
Agitator
Base Slot
Head
Cover
Belt Pulley
Motor
Shaft
New Belt
Agitator
Belt
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.